Cabletron Systems 9H42X-XX manual Creating and Editing a Basic Alarm

Page 51

Alarm Configuration

Before you decided whether or not to assign an action to a rising or falling alarm, it is

TIP important to understand something about the hysteresis function built in to the RMON alarm functionality. See How Rising and Falling Thresholds Work, page 3-27, for more information.

The remainder of the window fields provide the means for configuring alarms for each available interface. Note that the information provided in this screen is static

once it is displayed; for updated information, click on . Adding or modifying an alarm automatically updates the list.

Creating and Editing a Basic Alarm

The editable fields at the bottom of the Basic Alarm Configuration window allow you to configure alarm parameters for each available interface. These fields will display the parameters used for the most recently configured alarm (no matter which interfaces are selected in the list box); this allows you to set the same parameters on multiple interfaces with a single set. Hold down the Shift key while clicking to select a contiguous group of interfaces; use the Ctrl key to select any interfaces. To display the alarm parameters for a specific interface, double-click on that interface.

Note that there is no specific “Enable” function; simply configuring thresholds and/or actions for an alarm and applying those changes enables the alarm. For more information on disabling an alarm, see Disabling a Basic Alarm, page 3-9.

To configure an alarm:

1.At the top of the window, click to select the variable to be used for your alarm: Kilobits, Total Errors, or Broadcast/Multicast. The display in the list box will reflect the current status at each interface of the alarm type you have selected.

2.In the list box, click to highlight the interface (or use shift-clickor ctrl-clickto select multiple interfaces) for which you would like to configure an alarm for the selected variable. Note that the editable fields will display the parameters assigned to the most recently set alarm; however, any changes you make in these fields will be set to all selected interfaces.

3.In the Interval field, enter the amount of time, in seconds, over which the selected variable will be sampled. At the end of the interval, the sample value will be compared to both the rising and falling thresholds. You can assign any interval from 1 to 65,535.

4.In the Alarm field, click to select one or both of the following options:

a.Select Log if you wish to create a silent log of alarm occurrences.

b.Select Trap if you want your device to issue a trap in response to each alarm occurrence.

3-6

Basic Alarm Configuration

Image 51
Contents Cabletron Systems Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter Bridging Chapter StatisticsIndex Contents Viii Introduction Introduction Using the 9H42x-xx User’s Guide Related Manuals Software ConventionsCommon 9H42x-xx Window Fields MAC Address Device NameIP Address LocationUsing Buttons Using On-line HelpGetting Help Getting Help from Cabletron Systems’ Global Call Center 9H42x-xx FirmwareIntroduction 9H42x-xx Firmware From an individual device icon 9H42x-xx Module ViewFrom the MMAC-Plus Chassis View Viewing Module InformationPort Status Front Panel InformationConnection Status Up TimeTime Boot PromMenu Structure FirmwareDevice Menu H42x-xx Module View Menu StructureUtilities Menu Port Status MenuBridge Menu Help MenuPort Menu Port Status DisplaysStatus Selecting a Port Status ViewErrors LoadMapping Port Status Color Codes Chassis Manager WindowSpeed TypeChassis Manager Window To view the Chassis Manager window Viewing the Device TypeViewing I/F Summary Information UpTimeIndex Raw Counts DescriptionSta Interface Performance Statistics/Bar GraphsRate Address Viewing Interface DetailDiscarded ErrorUnicast Non-UnicastUsing the Find Source Address Feature Packets Transmitted Transmit onlyMaking Sense of Detail Statistics Configuring Ports Managing the ModuleStandard Mode Configuring Standard Ethernet PortsFull Duplex Fast Ethernet Configuration Configuring Fast Ethernet PortsLink State Current Operational ModeDesired Operational Mode Port TypeRemote Capabilities Advertised AbilitiesSetting the Desired Operational Mode 10. Edit Time Window Setting the Device Date and Time11. Edit Date Window Enabling and Disabling PortsTo enable or disable bridging for an individual interface 9H42x-xx Module View Managing the Module About Rmon Alarms and Events Alarm ConfigurationAlarm Configuration Basic Alarm ConfigurationRmon Basic Alarm Configuration Window Accessing the Basic Alarm Configuration WindowIf Number Viewing Alarm StatusKilobits Total Errors Broadcasts/Multicasts Port NumberRising Action Log/TrapPolling Interval Rising ThresholdCreating and Editing a Basic Alarm Alarm Configuration Alarm Configuration Viewing the Basic Alarm Log Disabling a Basic AlarmAlarm Configuration Accessing the Rmon Advanced Alarm/Event List Advanced Alarm ConfigurationAlarm Configuration Such as the Hosts component, not present, or Rmon Create/Edit Alarms Window Creating and Editing an Advanced AlarmAlarm Configuration Alarm Configuration Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window Alarm Configuration Adding Actions to an Event Rmon Create/Edit Actions Window Or deleted use the button to update the table at any time Viewing an Advanced Alarm Event Log Deleting an Alarm, Event, or ActionHow Rising and Falling Thresholds Work Event Statistics Accessing the Statistics WindowsRmon Statistics Tot. ErrorsDrop Events ProblemsBytes PacketsFrame Size Bytes Packets Viewing Total, Delta, and Accumulated Statistics Printing Statistics Interface StatisticsInterface Statistics Window Unicast Bridging Basics BridgingMore on Transparent Bridging An Overview of Bridge ManagementBridge Status Window Spanning Tree State Interface Type Bridge AddressInterface Speed From the Bridge Status window Enabling and Disabling All Installed InterfacesEnabling and Disabling Bridging Enabling and Disabling Individual InterfacesPerformance Graphs Bridge StatisticsForwarded Green Configuring the Bridge Performance Graphs Total Errors RedFiltered Magenta Xmitted BlueAltering the Ageing Time Using Source AddressingBridge Spanning Tree Bridge Spanning Tree Window Viewing Spanning Tree ParametersRoot Cost Bridge-level ParametersBridge Priority Root BridgeMax Age Forwarding DelayProtocol Hello TimePort-specific Parameters Changing Bridge Priority Changing Bridge Spanning Tree ParametersDesignated Port TopologyChanging the Spanning Tree Algorithm Protocol Type Changing Hello TimeChanging Max Age Time Changing Forwarding Delay Time Changing Port PriorityChanging Path Cost Dynamic, or Learned Filtering DatabaseFiltering Database Window Ageing Time ListNumber CapacityPort Filtering Configuring the Filtering DatabaseSource Port Receive PortChanging the Receive Port Changing the Type of EntryAdding or Deleting Individual Entries Changing the Port Filtering ActionClearing All Permanent, Static, or Dynamic Entries Configuring Duplex ModesTo access the Duplex Modes window Bridging Bridging Configuring Duplex Modes Numerics IndexIndex-2 Index-3 Index Index-4

9H42X-XX specifications

Cabletron Systems 9H42X-XX is an advanced networking device recognized for its robust performance and reliability in various enterprise environments. Designed to meet the growing demands of data communication, this model serves as a vital component of network infrastructure, offering a myriad of features and technologies.

One of the standout characteristics of the 9H42X-XX is its high-speed data processing capabilities. Equipped with multiple Gigabit Ethernet ports, it ensures rapid data transfer rates, making it ideal for bandwidth-intensive applications. This model supports both IPv4 and IPv6 addressing, ensuring compatibility with modern networking standards and future-proofing the investment for organizations transitioning to newer technologies.

The 9H42X-XX excels in flexibility and scalability, accommodating a range of networking topologies. Its modular design allows for the addition of different interface cards, catering to specific networking requirements such as VoIP, video streaming, and cloud services. This adaptiveness is crucial for organizations that must optimize their network as needs evolve over time.

Security is a primary consideration in the design of the 9H42X-XX. With built-in firewall capabilities and support for advanced encryption protocols, data integrity and confidentiality are ensured. Furthermore, the device offers robust access control features, allowing organizations to define user permissions and protect sensitive information from unauthorized access.

Another important feature is the comprehensive management options available with the 9H42X-XX. It provides a user-friendly interface for network administrators to monitor traffic, configure settings, and troubleshoot issues. This ease of management contributes to reduced downtimes and better overall network efficiency.

Additionally, the Cabletron Systems 9H42X-XX is known for its durability and performance consistency in varying environmental conditions. This resilience makes it suitable for both indoor and outdoor deployments, further extending its usability across different types of organizations.

In summary, the Cabletron Systems 9H42X-XX is a versatile networking solution that combines high-speed connectivity, security features, and ease of management within its robust architecture. Its adaptability and technical specifications position it as a reliable choice for enterprises looking to upgrade their network infrastructure and accommodate future growth.