Alarm Configuration

7.Since the first sample taken can be misleading, you can use the selections in the Startup Alarm box to disable either the rising or the falling threshold for that sample only. If you would like to exclude the falling alarm, select the Rising option; the first sample taken will only generate a rising alarm, even if the sample value is at or below the falling threshold. To exclude the rising alarm, select the Falling option; the first sample will then only generate a falling alarm, even if the sample value is at or above the rising threshold. If you wish to receive both alarms as appropriate, select the Both option.

8.Use the selections in the Sample Type box to indicate whether you want your threshold values compared to the total count for the variable (Absolute), or to the difference between the count at the end of the current interval and the count at the end of the previous interval (Delta). Make sure you have set your thresholds accordingly.

9.Click in the RisingThreshold field; enter the high threshold value for this alarm.

10.There are two ways to assign an event to your rising threshold: click in the RisingEventIndex text box and enter the number of the event you would like to see triggered if the rising threshold is crossed; or use the Events Watch list

in the main Alarm/Event window to highlight the desired event, then click on

. Be sure you assign the number of a valid event or there will be no response if the selected variable meets or crosses this threshold; assigning an index of zero effectively disables the threshold, as there will be no indication that it has been crossed.

For more information on how events are triggered, see How Rising and Falling Thresholds Work, page 3-27.

11.Click in the FallingThreshold field; enter the low threshold value for this alarm.

12.There are two ways to assign an event to your falling threshold: click in the FallingEventIndex text box and enter the number of the event you would like to see triggered if the falling threshold is crossed; or use the Events Watch list

in the main Alarm/Event window to highlight the desired event, then click on

. Again, be sure you assign the number of a valid event or there will be no response if the selected variable meets or crosses this threshold; assigning an index of zero effectively disables the threshold, as there will be no indication that it has been crossed.

For more information on how events are triggered, see How Rising and Falling Thresholds Work, page 3-27.

NOTE

There is no limit to the number of alarms that may be assigned to the same event.

Advanced Alarm Configuration

3-19

Image 64
Contents Cabletron Systems Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter Statistics Chapter BridgingIndex Contents Viii Introduction Introduction Using the 9H42x-xx User’s Guide Software Conventions Related ManualsCommon 9H42x-xx Window Fields Device Name IP AddressLocation MAC AddressUsing On-line Help Using ButtonsGetting Help 9H42x-xx Firmware Getting Help from Cabletron Systems’ Global Call CenterIntroduction 9H42x-xx Firmware 9H42x-xx Module View From an individual device iconViewing Module Information From the MMAC-Plus Chassis ViewFront Panel Information Connection StatusUp Time Port StatusBoot Prom Menu StructureFirmware TimeH42x-xx Module View Menu Structure Device MenuPort Status Menu Utilities MenuHelp Menu Bridge MenuPort Status Displays Port MenuSelecting a Port Status View StatusLoad ErrorsMapping Chassis Manager Window SpeedType Port Status Color CodesViewing the Device Type Chassis Manager Window To view the Chassis Manager windowUpTime Viewing I/F Summary InformationIndex Description StaInterface Performance Statistics/Bar Graphs Raw CountsRate Viewing Interface Detail AddressError UnicastNon-Unicast DiscardedPackets Transmitted Transmit only Using the Find Source Address FeatureMaking Sense of Detail Statistics Managing the Module Configuring PortsConfiguring Standard Ethernet Ports Standard ModeFull Duplex Configuring Fast Ethernet Ports Fast Ethernet ConfigurationCurrent Operational Mode Desired Operational ModePort Type Link StateAdvertised Abilities Remote CapabilitiesSetting the Desired Operational Mode Setting the Device Date and Time 10. Edit Time WindowEnabling and Disabling Ports 11. Edit Date WindowTo enable or disable bridging for an individual interface 9H42x-xx Module View Managing the Module Alarm Configuration About Rmon Alarms and EventsBasic Alarm Configuration Alarm ConfigurationAccessing the Basic Alarm Configuration Window Rmon Basic Alarm Configuration WindowViewing Alarm Status Kilobits Total Errors Broadcasts/MulticastsPort Number If NumberLog/Trap Polling IntervalRising Threshold Rising ActionCreating and Editing a Basic Alarm Alarm Configuration Alarm Configuration Disabling a Basic Alarm Viewing the Basic Alarm LogAlarm Configuration Advanced Alarm Configuration Accessing the Rmon Advanced Alarm/Event ListAlarm Configuration Such as the Hosts component, not present, or Creating and Editing an Advanced Alarm Rmon Create/Edit Alarms WindowAlarm Configuration Alarm Configuration Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window Alarm Configuration Adding Actions to an Event Rmon Create/Edit Actions Window Or deleted use the button to update the table at any time Deleting an Alarm, Event, or Action Viewing an Advanced Alarm Event LogHow Rising and Falling Thresholds Work Event Accessing the Statistics Windows StatisticsTot. Errors Rmon StatisticsProblems BytesPackets Drop EventsFrame Size Bytes Packets Viewing Total, Delta, and Accumulated Statistics Interface Statistics Printing StatisticsInterface Statistics Window Unicast Bridging Bridging BasicsAn Overview of Bridge Management More on Transparent BridgingBridge Status Window Spanning Tree State Bridge Address Interface TypeInterface Speed Enabling and Disabling All Installed Interfaces Enabling and Disabling BridgingEnabling and Disabling Individual Interfaces From the Bridge Status windowBridge Statistics Performance GraphsForwarded Green Total Errors Red Filtered MagentaXmitted Blue Configuring the Bridge Performance GraphsUsing Source Addressing Altering the Ageing TimeBridge Spanning Tree Viewing Spanning Tree Parameters Bridge Spanning Tree WindowBridge-level Parameters Bridge PriorityRoot Bridge Root CostForwarding Delay ProtocolHello Time Max AgePort-specific Parameters Changing Bridge Spanning Tree Parameters Designated PortTopology Changing Bridge PriorityChanging Hello Time Changing the Spanning Tree Algorithm Protocol TypeChanging Max Age Time Changing Port Priority Changing Forwarding Delay TimeChanging Path Cost Filtering Database Dynamic, or LearnedFiltering Database Window List NumberCapacity Ageing TimeConfiguring the Filtering Database Source PortReceive Port Port FilteringChanging the Type of Entry Changing the Receive PortChanging the Port Filtering Action Adding or Deleting Individual EntriesConfiguring Duplex Modes Clearing All Permanent, Static, or Dynamic EntriesTo access the Duplex Modes window Bridging Bridging Configuring Duplex Modes Index NumericsIndex-2 Index-3 Index Index-4

9H42X-XX specifications

Cabletron Systems 9H42X-XX is an advanced networking device recognized for its robust performance and reliability in various enterprise environments. Designed to meet the growing demands of data communication, this model serves as a vital component of network infrastructure, offering a myriad of features and technologies.

One of the standout characteristics of the 9H42X-XX is its high-speed data processing capabilities. Equipped with multiple Gigabit Ethernet ports, it ensures rapid data transfer rates, making it ideal for bandwidth-intensive applications. This model supports both IPv4 and IPv6 addressing, ensuring compatibility with modern networking standards and future-proofing the investment for organizations transitioning to newer technologies.

The 9H42X-XX excels in flexibility and scalability, accommodating a range of networking topologies. Its modular design allows for the addition of different interface cards, catering to specific networking requirements such as VoIP, video streaming, and cloud services. This adaptiveness is crucial for organizations that must optimize their network as needs evolve over time.

Security is a primary consideration in the design of the 9H42X-XX. With built-in firewall capabilities and support for advanced encryption protocols, data integrity and confidentiality are ensured. Furthermore, the device offers robust access control features, allowing organizations to define user permissions and protect sensitive information from unauthorized access.

Another important feature is the comprehensive management options available with the 9H42X-XX. It provides a user-friendly interface for network administrators to monitor traffic, configure settings, and troubleshoot issues. This ease of management contributes to reduced downtimes and better overall network efficiency.

Additionally, the Cabletron Systems 9H42X-XX is known for its durability and performance consistency in varying environmental conditions. This resilience makes it suitable for both indoor and outdoor deployments, further extending its usability across different types of organizations.

In summary, the Cabletron Systems 9H42X-XX is a versatile networking solution that combines high-speed connectivity, security features, and ease of management within its robust architecture. Its adaptability and technical specifications position it as a reliable choice for enterprises looking to upgrade their network infrastructure and accommodate future growth.