Chapter 3

Operation

The 9T122-24 MicroLAN Module provides connectivity between the front panel Token Ring(s) and the FDDI rings on the backplane (FNB-1 or FNB-2).

MMAC-Plus modules connect to either the Internal Network Bus (INB) or the Flexible Network Bus (FNB) bus. The 9T122-24 module connects to the FNB bus. Shown in Figure 3-1is a block diagram of the module. The front panel may be configured as one Token Ring (factory default) or as two rings. In the two ring configuration, the rings function as individual networks, each with twelve ports. Bridging/Routing may occur between these two rings and/or to any other MMAC-Plus module via the Flexible Network Bus.

DC/DC

Converter

Twelve

Front Panel

Connections

Twelve

Front Panel

Connections

System

Diagnostic

Controller

i960 PLUS Core

SMB-1

SMB-10

FNB-1 or

FNB-2

Figure 3-1. 9T122-24 Block Diagram

Bridging

The 9T122-24 is configured for SRT bridging. It will pass SR (Source Routing) frames between the rings and provides translation to transparent frames over the FNB to Ethernet and FDDI modules. For information on configuring the bridging function, see the addendum to the MMAC-Plus Local Management User’s Guide, containing information specific to this model.

3-1

Image 17
Contents Page Page Vcci Notice FCC NoticeDOC Notice Contents Introduction FeaturesManagement Information Base MIB Support Features Getting Help Related ManualsInstalling the MicroLAN Module InstallationInstallation Reset Switch SMB-1 Prom User Accessible ComponentsLocation of Module DIP Switch Setting the Module Card DIP SwitchSwitch Function Description Multi-Ring Out Capability Ring SpeedBridging OperationTransparent Bridging Spanning Tree Algorithm System Management Buses Flexible Network Bus FNBDC/DC Converter System Diagnostic ControllerFNB Interface I960 CoreLanview LEDs Lanview LEDsLED Color State Description LED Color State Yellow 16 Mbs Off Mps Specifications SafetyService Electrical Physical