Cabletron Systems 7000 manual Load, Errors

Page 27

The SmartSwitch 7000 Chassis View

¥LIS (Listening) if the port is not adding information to the Þltering database. It is monitoring Bridge Protocol Data Unit (BPDU) trafÞc while preparing to move to the forwarding state.

¥LRN (Learning) if the Forwarding database is being created, or the Spanning Tree Algorithm is being executed because of a network topology change. The port is monitoring network trafÞc, and learning network addresses.

¥BLK (Blocking) if the port is on-line, but Þltering trafÞc from going across the SmartSwitch 7000 from one network segment to another. Bridge topology information will be forwarded by the port.

¥BRK (Broken) if the physical interface has malfunctioned.

If you have selected Bridge Mapping, the port status boxes will display the bridge interface index numbers assigned to each interface (which may or may not match the ifIndex values displayed via the I/F Mapping option described below).

If you have selected the Admin status mode, a port is considered:

¥ON if the port is enabled by management.

¥OFF if it has not been enabled or if it has been disabled through management action.

Note that the Admin state reßects the state requested by management; depending on the circumstances, this may or may not match the current Operator status, described below.

If you have selected the Operator status mode, a port is considered:

¥ON if the port is currently forwarding packets.

¥OFF if the port is not currently forwarding packets.

Note that the Operator status provides the actual status of the port; depending on the circumstances, this may or may not reßect the Admin state currently requested by management. For example, ports which are administratively ON but not yet connected would display an Operator status of OFF, since no packets are being forwarded.

Load

If you choose Load, the interface text boxes will display the percentage of network load processed by each port during the last polling interval. This percentage reßects the network load generated per polling interval by devices connected to the port compared to the theoretical maximum load (10 or 100 Mbits/sec) of the connected network.

Errors

If you choose the Errors mode, the interface boxes will display the percentage of the total number of valid packets processed by each port during the last polling interval that were error packets. This percentage reßects the number of errors

Viewing Chassis Information

2-11

Image 27
Contents SmartSwitch User’s Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Index Chapter Alarm ConfigurationChapter Fddi Management Chapter ATM ConfigurationIntroduction Introduction Using the SmartSwitch 7000 User’s Guide Related Manuals Software ConventionsCommon Window Fields MAC Address Device NameIP Address LocationLeft Mouse Button Right Mouse Button Using the MouseUsing Window Buttons Using On-line HelpGetting Help Getting Help from the Cabletron Systems Global Call Center SmartSwitch 7000 FirmwareSmartSwitch Chassis View Viewing Chassis Information SmartSwitch 7000 Chassis ViewSmartSwitch Chassis View Windows Port Status Front Panel InformationConnection Status UpTimeTime Boot PromMenu Structure FirmwareDevice Menu SmartSwitch 7000 Chassis View Menu StructurePort Status Menu Fddi Menu Utilities MenuHelp Menu Port Menus Board MenusPort Status Displays Selecting a Port Status ViewStatus Load ErrorsPort Status Color Codes Chassis Manager WindowSpeed TypeChassis Manager Window Viewing Hardware TypesModule Type Device TypeIndex Viewing I/F Summary InformationInterface Performance Statistics/Bar Graphs DescriptionPhysical Status Logical StatusRate Address Viewing Interface DetailDiscarded ErrorUnicast Non-UnicastViewing Fddi Statistics Packets Transmitted Transmit onlyMaking Sense of Detail Statistics Peak KBytes/sec Setting the Fddi Statistics Polling IntervalFrames/sec KBytes/sec11. Find Source Address Window Using the Find Source Address FeatureManaging the Hub Configuring PortsConfiguring Ethernet and Fddi Ports Standard Mode Full DuplexConfiguring Fast Ethernet Ports 13. Fast Ethernet ConÞguration Link State Current Operational ModeDesired Operational Mode Port TypeRemote Capabilities Setting the Desired Operational ModeFor 100Base-FX ports, options are COM Port Admin Configuring the COM PortsCOM Port Function Speed Selection Slip16. Edit Date Window Setting the Device Date and TimeEnabling and Disabling Ports Statistics Accessing the Statistics WindowStatistics Rmon StatisticsPacket Type BytesPackets Drop EventsProblems Frame Size Bytes Packets Viewing Total, Delta, and Accumulated StatisticsStandard Print Window Printing StatisticsInterface Statistics Interface Statistics Packets Transmitted Transmit only Statistics About Rmon Alarms and Events Alarm ConfigurationAlarm Configuration Basic Alarm ConfigurationRmon Basic Alarm ConÞguration Window Accessing the Basic Alarm Configuration WindowIf Number Viewing Alarm StatusKilobits Total Errors Broadcasts/Multicasts Port NumberRising Threshold If TypeLog/Trap Polling IntervalCreating and Editing a Basic Alarm Alarm Configuration Falling Thresholds Work, Disabling a Basic AlarmViewing the Basic Alarm Log Accessing the Rmon Advanced Alarm/Event List Advanced Alarm ConfigurationRmon Advanced Alarm/Event List Window Alarm Configuration Creating and Editing an Advanced Alarm To conÞgure an alarm TIP Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window TIP Alarm Configuration Adding Actions to an Event Alarm Configuration Viewing an Advanced Alarm Event Log Deleting an Alarm, Event, or ActionHow Rising and Falling Thresholds Work Event Alarm Configuration How Rising and Falling Thresholds Work Fddi Management Fddi Management ConfigurationMAC State Concentrator ConÞguration WindowReq. Requested Target Token Rotation Time SMT VersionNumber of MACs Neg. NegotiatedConcentrator M Ports Concentrator Non-M PortsRing Configuration Connection PolicyFddi Management 15 32,768 Ñ a permanently set value for this bit Address Mode Station ListNumber of Nodes Upstream Neighbor Stations PanelNode Class TopologyPerformance Lost Frames Frame ErrorsTransmit Frames Receive FramesATM Configuration Accessing the ATM Connections WindowConnection Data VPI SettingsAdding a New Connection Configuring ConnectionsDeleting a Connection ATM Configuration Configuring Connections Numerics SymbolsIndex-2 Index-3 Index Index-4