Cabletron Systems 7000 manual Viewing Alarm Status, Kilobits Total Errors Broadcasts/Multicasts

Page 62

Alarm Configuration

When the window is Þrst launched, no interfaces will be selected, and the

, , and buttons will be grayed out: and

will activate when an interface is selected; will activate when an interface which has experienced an alarm event is selected. The presence of an event log is indicated by the double greater-than sign (>>) displayed to the left of the threshold value that was crossed.

Viewing Alarm Status

The Basic Alarm ConÞguration window contains all the Þelds you need to conÞgure one or more of the three basic alarms available for each interface installed in your RMON device:

Kilobits — Total Errors — Broadcasts/Multicasts

Use these Þelds at the top of the window to change the alarm type whose status is displayed in the list box. For example, if the Kilobits option is selected, the information in the list box pertains to the status of the Kilobits alarm type for each installed interface. Before you conÞgure an alarm or alarms, be sure the appropriate option is selected here.

The available alarm variables are:

¥Kilobits (ifInOctets) Ñ tracks the number of octets of data received by the selected interface. Note that this value has been converted for you from octets (or bytes) to kilobits (or units of 125 bytes); be sure to enter your thresholds accordingly. For example, to set a rising threshold of 1250 octets, enter a threshold value of 10; to set a falling threshold of 625 octets, enter a threshold value of 5.

¥Total Errors (ifInErrors) Ñ tracks the number of error packets received by the selected interface.

¥Broadcast/Multicast (ifInNUcast) Ñ tracks the number of non-unicast Ñ that is, broadcast or multicast Ñ packets received by the selected interface.

Note that the three pre-selected alarm variables are all MIB II variables; this allows you to

TIP conÞgure alarms for any installed interface Ñ even those for which no speciÞc RMON statistics yet exist.

Port Number

Provides a sequential indexing of the interfaces installed in your RMON device.

IF Number

Displays the interface number assigned to each available interface. Interfaces installed in a SmartSwitch 7000 chassis are indexed according to an XXXXYY scheme, where X = the slot number in which the module containing the port resides, times 10,000; and Y = the physical index assigned to the port. For example, an interface number of 30002 would refer to port 2 on the module installed in slot 3 of the chassis.

4-4

Basic Alarm Configuration

Image 62
Contents SmartSwitch User’s Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter ATM Configuration Chapter Alarm ConfigurationChapter Fddi Management IndexIntroduction Introduction Using the SmartSwitch 7000 User’s Guide Common Window Fields Related ManualsSoftware Conventions Location Device NameIP Address MAC AddressUsing the Mouse Left Mouse Button Right Mouse ButtonGetting Help Using Window ButtonsUsing On-line Help SmartSwitch 7000 Firmware Getting Help from the Cabletron Systems Global Call CenterSmartSwitch Chassis View SmartSwitch 7000 Chassis View Viewing Chassis InformationSmartSwitch Chassis View Windows UpTime Front Panel InformationConnection Status Port StatusFirmware Boot PromMenu Structure TimeSmartSwitch 7000 Chassis View Menu Structure Device MenuPort Status Menu Help Menu Fddi MenuUtilities Menu Board Menus Port MenusStatus Port Status DisplaysSelecting a Port Status View Errors LoadType Chassis Manager WindowSpeed Port Status Color CodesViewing Hardware Types Chassis Manager WindowDevice Type Module TypeViewing I/F Summary Information IndexLogical Status DescriptionPhysical Status Interface Performance Statistics/Bar GraphsRate Viewing Interface Detail AddressNon-Unicast ErrorUnicast DiscardedMaking Sense of Detail Statistics Viewing Fddi StatisticsPackets Transmitted Transmit only KBytes/sec Setting the Fddi Statistics Polling IntervalFrames/sec Peak KBytes/secUsing the Find Source Address Feature 11. Find Source Address WindowConfiguring Ethernet and Fddi Ports Managing the HubConfiguring Ports Configuring Fast Ethernet Ports Standard ModeFull Duplex 13. Fast Ethernet ConÞguration Port Type Current Operational ModeDesired Operational Mode Link StateSetting the Desired Operational Mode Remote CapabilitiesFor 100Base-FX ports, options are COM Port Function COM Port AdminConfiguring the COM Ports Slip Speed SelectionSetting the Device Date and Time 16. Edit Date WindowEnabling and Disabling Ports Accessing the Statistics Window StatisticsRmon Statistics StatisticsDrop Events BytesPackets Packet TypeProblems Viewing Total, Delta, and Accumulated Statistics Frame Size Bytes PacketsPrinting Statistics Standard Print WindowInterface Statistics Interface Statistics Packets Transmitted Transmit only Statistics Alarm Configuration About Rmon Alarms and EventsBasic Alarm Configuration Alarm ConfigurationAccessing the Basic Alarm Configuration Window Rmon Basic Alarm ConÞguration WindowPort Number Viewing Alarm StatusKilobits Total Errors Broadcasts/Multicasts If NumberPolling Interval If TypeLog/Trap Rising ThresholdCreating and Editing a Basic Alarm Alarm Configuration Disabling a Basic Alarm Falling Thresholds Work,Viewing the Basic Alarm Log Advanced Alarm Configuration Accessing the Rmon Advanced Alarm/Event ListRmon Advanced Alarm/Event List Window Alarm Configuration Creating and Editing an Advanced Alarm To conÞgure an alarm TIP Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window TIP Alarm Configuration Adding Actions to an Event Alarm Configuration Deleting an Alarm, Event, or Action Viewing an Advanced Alarm Event LogHow Rising and Falling Thresholds Work Event Alarm Configuration How Rising and Falling Thresholds Work Fddi Management Configuration Fddi ManagementConcentrator ConÞguration Window MAC StateSMT Version Req. Requested Target Token Rotation TimeConcentrator Non-M Ports Neg. NegotiatedConcentrator M Ports Number of MACsConnection Policy Ring ConfigurationFddi Management 15 32,768 Ñ a permanently set value for this bit Number of Nodes Address ModeStation List Topology Stations PanelNode Class Upstream NeighborPerformance Receive Frames Frame ErrorsTransmit Frames Lost FramesAccessing the ATM Connections Window ATM ConfigurationConnection Data Settings VPIConfiguring Connections Adding a New ConnectionDeleting a Connection ATM Configuration Configuring Connections Symbols NumericsIndex-2 Index-3 Index Index-4