Cabletron Systems 7000 manual If Type, Log/Trap, Polling Interval, Rising Threshold, Rising Action

Page 63

Alarm Configuration

IF Type

Displays each interfaceÕs type: FDDI, Ethernet, Token Ring, or ATM. Note that there is no type distinction between standard Ethernet and Fast Ethernet.

Status

Displays the current status of the selected alarm type for each interface: Enabled or Disabled. Remember, this status refers only to the alarm type which is selected at the top of the window; each of the other two alarm types can have different states.

Log/Trap

Indicates whether or not each alarm has been conÞgured to create a silent log of event occurrences and the alarms that triggered them, and whether or not each alarm has been conÞgured to issue a trap in response to a rising or falling alarm condition. Possible values are log, trap, log&trap, or none.

Polling Interval

Displays the amount of time, in seconds, over which the selected alarm variable will be sampled. At the end of the interval, the sample value will be compared to both the rising and falling thresholds (described below). You can set any interval from 1 to 65,535 seconds.

Rising Threshold

Displays the high threshold value set for the selected alarm variable. Values used to compare to the thresholds are relative, or delta values (the difference between the value counted at the end of the current interval and the value counted at the end of the previous interval); be sure to set your thresholds accordingly.

Rising Action

Indicates whether or not a rising alarm occurrence will initiate any actions in response to the alarm condition: Enable if bridging will be enabled at the selected interface in response to a rising alarm, Disable if bridging will be disabled at the selected interface in response to a rising alarm, and None if no actions have been conÞgured for the selected alarm. Note that the Action Þelds will be unavailable for devices conÞgured to operate in SecureFast switching mode.

Falling Threshold

Displays the low threshold value set for the selected alarm variable. Values used to compare to the thresholds are relative, or delta values (the difference between the value counted at the end of the current interval and the value counted at the end of the previous interval); be sure to set your thresholds accordingly.

Falling Action

Indicates whether or not a falling alarm occurrence will initiate any actions in response to the alarm condition: Enable if bridging will be enabled at the selected interface in response to a falling alarm, Disable if bridging will be disabled in response to a falling alarm, and None if no actions have been conÞgured for the selected alarm. Note that the Action Þelds will be unavailable for devices conÞgured to operate in SecureFast switching mode.

Basic Alarm Configuration

4-5

Image 63
Contents SmartSwitch User’s Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Index Chapter Alarm ConfigurationChapter Fddi Management Chapter ATM ConfigurationIntroduction Introduction Using the SmartSwitch 7000 User’s Guide Related Manuals Software ConventionsCommon Window Fields MAC Address Device NameIP Address LocationLeft Mouse Button Right Mouse Button Using the MouseUsing Window Buttons Using On-line HelpGetting Help Getting Help from the Cabletron Systems Global Call Center SmartSwitch 7000 FirmwareSmartSwitch Chassis View Viewing Chassis Information SmartSwitch 7000 Chassis ViewSmartSwitch Chassis View Windows Port Status Front Panel InformationConnection Status UpTimeTime Boot PromMenu Structure FirmwareDevice Menu SmartSwitch 7000 Chassis View Menu StructurePort Status Menu Fddi Menu Utilities MenuHelp Menu Port Menus Board MenusPort Status Displays Selecting a Port Status ViewStatus Load ErrorsPort Status Color Codes Chassis Manager WindowSpeed TypeChassis Manager Window Viewing Hardware TypesModule Type Device TypeIndex Viewing I/F Summary InformationInterface Performance Statistics/Bar Graphs DescriptionPhysical Status Logical StatusRate Address Viewing Interface DetailDiscarded ErrorUnicast Non-UnicastViewing Fddi Statistics Packets Transmitted Transmit onlyMaking Sense of Detail Statistics Peak KBytes/sec Setting the Fddi Statistics Polling IntervalFrames/sec KBytes/sec11. Find Source Address Window Using the Find Source Address FeatureManaging the Hub Configuring PortsConfiguring Ethernet and Fddi Ports Standard Mode Full DuplexConfiguring Fast Ethernet Ports 13. Fast Ethernet ConÞguration Link State Current Operational ModeDesired Operational Mode Port TypeRemote Capabilities Setting the Desired Operational ModeFor 100Base-FX ports, options are COM Port Admin Configuring the COM PortsCOM Port Function Speed Selection Slip16. Edit Date Window Setting the Device Date and TimeEnabling and Disabling Ports Statistics Accessing the Statistics WindowStatistics Rmon StatisticsPacket Type BytesPackets Drop EventsProblems Frame Size Bytes Packets Viewing Total, Delta, and Accumulated StatisticsStandard Print Window Printing StatisticsInterface Statistics Interface Statistics Packets Transmitted Transmit only Statistics About Rmon Alarms and Events Alarm ConfigurationAlarm Configuration Basic Alarm ConfigurationRmon Basic Alarm ConÞguration Window Accessing the Basic Alarm Configuration WindowIf Number Viewing Alarm StatusKilobits Total Errors Broadcasts/Multicasts Port NumberRising Threshold If TypeLog/Trap Polling IntervalCreating and Editing a Basic Alarm Alarm Configuration Falling Thresholds Work, Disabling a Basic AlarmViewing the Basic Alarm Log Accessing the Rmon Advanced Alarm/Event List Advanced Alarm ConfigurationRmon Advanced Alarm/Event List Window Alarm Configuration Creating and Editing an Advanced Alarm To conÞgure an alarm TIP Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window TIP Alarm Configuration Adding Actions to an Event Alarm Configuration Viewing an Advanced Alarm Event Log Deleting an Alarm, Event, or ActionHow Rising and Falling Thresholds Work Event Alarm Configuration How Rising and Falling Thresholds Work Fddi Management Fddi Management ConfigurationMAC State Concentrator ConÞguration WindowReq. Requested Target Token Rotation Time SMT VersionNumber of MACs Neg. NegotiatedConcentrator M Ports Concentrator Non-M PortsRing Configuration Connection PolicyFddi Management 15 32,768 Ñ a permanently set value for this bit Address Mode Station ListNumber of Nodes Upstream Neighbor Stations PanelNode Class TopologyPerformance Lost Frames Frame ErrorsTransmit Frames Receive FramesATM Configuration Accessing the ATM Connections WindowConnection Data VPI SettingsAdding a New Connection Configuring ConnectionsDeleting a Connection ATM Configuration Configuring Connections Numerics SymbolsIndex-2 Index-3 Index Index-4