Cabletron Systems 7000 manual Configuring the COM Ports, COM Port Admin, COM Port Function

Page 45

The SmartSwitch 7000 Chassis View

changes to be completely initialized, particularly if the link partners must negotiate or re-negotiate the mode; you may need to refresh the window a few times before current operational data is displayed.

Configuring the COM Ports

You can use the COM Port ConÞguration window (Figure 2-14) to specify the functions each of the RS232 COM ports on the 7X00 Control Module face will perform. To do so:

1.Click on Device in the Chassis View menu bar to display the Device menu.

2.Drag down to COM Port Configuration, then right to select Port 1 or Port 2, and release. The COM Port Configuration window,Figure 2-14, will appear.

Figure 2-14. COM Port ConÞguration

You can use the COM Port ConÞguration window to set the following operating parameters:

COM Port Admin

Use this Þeld to administratively enable or disable the selected COM port.

COM Port Function

Use this Þeld to select the function for which you wish to use the selected COM port:

LM

Local Management: select this option if you wish to connect a

 

terminal to the selected COM port from which to run Local

 

Management.

UPS

Select this option if you wish to connect an uninterruptable

 

power supply (UPS) to the selected COM Port. Note that if you

 

select this option, an additional option Ñ UPS Ñ will appear on

 

the Device menu; use the resulting window to conÞgure speciÞc

 

UPS settings.

Managing the Hub

2-29

Image 45
Contents SmartSwitch User’s Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter Fddi Management Chapter Alarm ConfigurationChapter ATM Configuration IndexIntroduction Introduction Using the SmartSwitch 7000 User’s Guide Related Manuals Software ConventionsCommon Window Fields IP Address Device NameLocation MAC AddressLeft Mouse Button Right Mouse Button Using the MouseUsing Window Buttons Using On-line HelpGetting Help Getting Help from the Cabletron Systems Global Call Center SmartSwitch 7000 FirmwareSmartSwitch Chassis View Viewing Chassis Information SmartSwitch 7000 Chassis ViewSmartSwitch Chassis View Windows Connection Status Front Panel InformationUpTime Port StatusMenu Structure Boot PromFirmware TimeDevice Menu SmartSwitch 7000 Chassis View Menu StructurePort Status Menu Fddi Menu Utilities MenuHelp Menu Port Menus Board MenusPort Status Displays Selecting a Port Status ViewStatus Load ErrorsSpeed Chassis Manager WindowType Port Status Color CodesChassis Manager Window Viewing Hardware TypesModule Type Device TypeIndex Viewing I/F Summary InformationPhysical Status DescriptionLogical Status Interface Performance Statistics/Bar GraphsRate Address Viewing Interface DetailUnicast ErrorNon-Unicast DiscardedViewing Fddi Statistics Packets Transmitted Transmit onlyMaking Sense of Detail Statistics Frames/sec Setting the Fddi Statistics Polling IntervalKBytes/sec Peak KBytes/sec11. Find Source Address Window Using the Find Source Address FeatureManaging the Hub Configuring PortsConfiguring Ethernet and Fddi Ports Standard Mode Full DuplexConfiguring Fast Ethernet Ports 13. Fast Ethernet ConÞguration Desired Operational Mode Current Operational ModePort Type Link StateRemote Capabilities Setting the Desired Operational ModeFor 100Base-FX ports, options are COM Port Admin Configuring the COM PortsCOM Port Function Speed Selection Slip16. Edit Date Window Setting the Device Date and TimeEnabling and Disabling Ports Statistics Accessing the Statistics WindowStatistics Rmon StatisticsPackets BytesDrop Events Packet TypeProblems Frame Size Bytes Packets Viewing Total, Delta, and Accumulated StatisticsStandard Print Window Printing StatisticsInterface Statistics Interface Statistics Packets Transmitted Transmit only Statistics About Rmon Alarms and Events Alarm ConfigurationAlarm Configuration Basic Alarm ConfigurationRmon Basic Alarm ConÞguration Window Accessing the Basic Alarm Configuration WindowKilobits Total Errors Broadcasts/Multicasts Viewing Alarm StatusPort Number If NumberLog/Trap If TypePolling Interval Rising ThresholdCreating and Editing a Basic Alarm Alarm Configuration Falling Thresholds Work, Disabling a Basic AlarmViewing the Basic Alarm Log Accessing the Rmon Advanced Alarm/Event List Advanced Alarm ConfigurationRmon Advanced Alarm/Event List Window Alarm Configuration Creating and Editing an Advanced Alarm To conÞgure an alarm TIP Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window TIP Alarm Configuration Adding Actions to an Event Alarm Configuration Viewing an Advanced Alarm Event Log Deleting an Alarm, Event, or ActionHow Rising and Falling Thresholds Work Event Alarm Configuration How Rising and Falling Thresholds Work Fddi Management Fddi Management ConfigurationMAC State Concentrator ConÞguration WindowReq. Requested Target Token Rotation Time SMT VersionConcentrator M Ports Neg. NegotiatedConcentrator Non-M Ports Number of MACsRing Configuration Connection PolicyFddi Management 15 32,768 Ñ a permanently set value for this bit Address Mode Station ListNumber of Nodes Node Class Stations PanelTopology Upstream NeighborPerformance Transmit Frames Frame ErrorsReceive Frames Lost FramesATM Configuration Accessing the ATM Connections WindowConnection Data VPI SettingsAdding a New Connection Configuring ConnectionsDeleting a Connection ATM Configuration Configuring Connections Numerics SymbolsIndex-2 Index-3 Index Index-4