Cabletron Systems 7000 manual Concentrator ConÞguration Window, MAC State

Page 89

FDDI Management

Figure 5-2. The Concentrator ConÞguration Window

MAC State

This Þeld indicates the current state of the selecting ringÕs MAC component. (The RMT component of SMT monitors MAC operation and takes actions necessary to aid in achieving an operational ring.) Possible states are:

Not Available

There is no MAC on the FDDI ring associated with the

 

SMT entity.

Ring-Op

The ring is functioning normally. While in this state, the

 

MAC being managed is part of an operational FDDI ring.

Isolated

SMT has just initialized RMT or RMT has entered this

 

state during a path test (trace) after ring beaconing; RMT

 

is not aware of the ring path or state.

Non-Op

The MAC being managed by the selected SMT is

 

participating in ring recovery; the ring is not operational.

Detect

The claim (beacon) process of the FDDI ring protocol has

 

exceeded one second. There may be a problem on the

 

ring; any duplicate address conditions are being

 

detected. In this state, the ring is still alive, but no data is

 

being transmitted.

Non-Op-Dup

The ring is not operational; the address of the MAC

 

under control of the SMT entity has been found to

 

duplicate that of another MAC on the ring. The duplicate

 

address condition prevented ring recovery and

 

initialization after a claim and beacon process. This state

 

will not occur unless you are using locally- administered

 

addresses, as factory-set MAC addresses are guaranteed

 

to be unique.

Ring-Op-Dup

The ring is operational; however, the address of the MAC

 

under control of the SMT entity has been found to

 

duplicate that of another MAC on the ring. Corrective

 

actions will be attempted before the duplicate address

Configuration

5-3

Image 89
Contents SmartSwitch User’s Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter Fddi Management Chapter Alarm ConfigurationChapter ATM Configuration IndexIntroduction Introduction Using the SmartSwitch 7000 User’s Guide Common Window Fields Related ManualsSoftware Conventions IP Address Device NameLocation MAC AddressLeft Mouse Button Right Mouse Button Using the MouseGetting Help Using Window ButtonsUsing On-line Help Getting Help from the Cabletron Systems Global Call Center SmartSwitch 7000 FirmwareSmartSwitch Chassis View Viewing Chassis Information SmartSwitch 7000 Chassis ViewSmartSwitch Chassis View Windows Connection Status Front Panel InformationUpTime Port StatusMenu Structure Boot PromFirmware TimeDevice Menu SmartSwitch 7000 Chassis View Menu StructurePort Status Menu Help Menu Fddi MenuUtilities Menu Port Menus Board MenusStatus Port Status DisplaysSelecting a Port Status View Load ErrorsSpeed Chassis Manager WindowType Port Status Color CodesChassis Manager Window Viewing Hardware TypesModule Type Device TypeIndex Viewing I/F Summary InformationPhysical Status DescriptionLogical Status Interface Performance Statistics/Bar GraphsRate Address Viewing Interface DetailUnicast ErrorNon-Unicast DiscardedMaking Sense of Detail Statistics Viewing Fddi StatisticsPackets Transmitted Transmit only Frames/sec Setting the Fddi Statistics Polling IntervalKBytes/sec Peak KBytes/sec11. Find Source Address Window Using the Find Source Address FeatureConfiguring Ethernet and Fddi Ports Managing the HubConfiguring Ports Configuring Fast Ethernet Ports Standard ModeFull Duplex 13. Fast Ethernet ConÞguration Desired Operational Mode Current Operational ModePort Type Link StateRemote Capabilities Setting the Desired Operational ModeFor 100Base-FX ports, options are COM Port Function COM Port AdminConfiguring the COM Ports Speed Selection Slip16. Edit Date Window Setting the Device Date and TimeEnabling and Disabling Ports Statistics Accessing the Statistics WindowStatistics Rmon StatisticsPackets BytesDrop Events Packet TypeProblems Frame Size Bytes Packets Viewing Total, Delta, and Accumulated StatisticsStandard Print Window Printing StatisticsInterface Statistics Interface Statistics Packets Transmitted Transmit only Statistics About Rmon Alarms and Events Alarm ConfigurationAlarm Configuration Basic Alarm ConfigurationRmon Basic Alarm ConÞguration Window Accessing the Basic Alarm Configuration WindowKilobits Total Errors Broadcasts/Multicasts Viewing Alarm StatusPort Number If NumberLog/Trap If TypePolling Interval Rising ThresholdCreating and Editing a Basic Alarm Alarm Configuration Falling Thresholds Work, Disabling a Basic AlarmViewing the Basic Alarm Log Accessing the Rmon Advanced Alarm/Event List Advanced Alarm ConfigurationRmon Advanced Alarm/Event List Window Alarm Configuration Creating and Editing an Advanced Alarm To conÞgure an alarm TIP Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window TIP Alarm Configuration Adding Actions to an Event Alarm Configuration Viewing an Advanced Alarm Event Log Deleting an Alarm, Event, or ActionHow Rising and Falling Thresholds Work Event Alarm Configuration How Rising and Falling Thresholds Work Fddi Management Fddi Management ConfigurationMAC State Concentrator ConÞguration WindowReq. Requested Target Token Rotation Time SMT VersionConcentrator M Ports Neg. NegotiatedConcentrator Non-M Ports Number of MACsRing Configuration Connection PolicyFddi Management 15 32,768 Ñ a permanently set value for this bit Number of Nodes Address ModeStation List Node Class Stations PanelTopology Upstream NeighborPerformance Transmit Frames Frame ErrorsReceive Frames Lost FramesATM Configuration Accessing the ATM Connections WindowConnection Data VPI SettingsAdding a New Connection Configuring ConnectionsDeleting a Connection ATM Configuration Configuring Connections Numerics SymbolsIndex-2 Index-3 Index Index-4