14. OTHERS

14-1 Troubleshooting (Cont'd)

In the case of troubles occurring during operation of the GY-DV550, it performs a self-test to identify the cause and displays the result in the form of an error code. The error code consists of the "main code" which indicates its contents and the "sub-code" which indicates the details. Depending on the status of the GY-DV550 at this time, indications may also appear on the LCD display, the WARNING indicator may activate and the alarm tone may be generated.

In the viewfinder, the "VTR WARNING (DEW)" indication appears when condensation is detected, and the "VTR WARNING (STOP)", "VTR WARNING (HARD)" or "VTR WARNING (REW)" indication appears depending on the contents of the error code when some of the other error codes are displayed.

TALLY lamp

VTR WARNING (HARD)

VTR WARNING (DEW)

WARNING indicator

 

 

 

 

 

 

 

TALLY

 

 

 

OPERATE/WARNING

 

 

 

lamp

 

 

 

RESET

LIGHT

 

MODE

 

 

 

ON

 

RM

 

 

 

 

OFF

 

VTR

 

 

 

MONITOR

COUNTER

 

INCOM

FILTER

 

 

SELECT

 

MIC

 

 

ALARM

CH-1

CTL

CARBON

 

1 3200k

 

MIX

TC

DYNAMIC

 

2 5600k+1/8ND

 

 

CH-2

UB

 

 

 

3 5600k+1/64ND

 

 

 

 

 

 

 

 

 

 

 

 

INCOM

 

 

SHUTTER STATUS

 

MONITOR

 

 

MIC

LEVEL

 

 

 

ON

MENU

 

 

AUTO

FRONT

 

 

 

 

 

MANUAL

REAR

 

 

 

 

 

 

AUDIO SELECT

AUDIO INPUT

OFF

 

 

 

 

 

CH-1 AUDIO CH-2

 

CALL

 

 

 

 

LEVEL

 

 

 

 

 

 

 

RM

OFF

DC IN

 

 

 

 

 

 

 

/BATT.

 

 

 

 

 

 

POWER

 

NG

OPERATE

 

 

 

 

 

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

EARPHONE

 

 

 

ALARM

 

 

 

 

 

 

 

tone

 

 

 

Auto-OFF indicator:

Lights depending on the error code. When this indicator lights, the GY-DV550 will automatically stop operation or eject the cassette.

The GY-DV550 does not accept any operation.

Dew condensation indicator

AUTO OFF DEW

Main code

Sub-code

WARNING indicator

Alarm Tone

Display

GY-DV550 Operation

 

 

 

 

Red, blinking

Continuous

"Error code"

• Automatically ejects the cassette. It can be inserted again.

 

 

 

 

 

 

"Error code"

• Automatically stops operation or ejects the cassette.

 

 

plus

(Auto OFF) * The GY-DV550 does not accept any operation.

 

 

"AUTO OFF"

 

 

 

 

 

Red, blinking

Intermittent

"DEW "

• Dew condensation inside the unit.

 

 

 

The GY-DV550 does not accept any operation until the DEW indicator

 

 

 

disappears from the display.

 

 

 

 

*In the Auto OFF status, it is impossible to operate the GY- DV550. This condition can be cancelled by switching the OPERATE switch OFF and then switching it ON again. If the same problem occurs again after the power is turned ON, there may be something wrong with the GY-DV550. Please consult the person in charge of professional video equipment at your nearest JVC-authorized service agent.

*If the display operates abnormally, Press the RESET switch inside the lithium battery case, and then set the OPERATE switch to ON again. (See page 36)

Please note that pressing the RESET switch will also reset the time code data and time and date data.

The GY-DV550 is a microcomputer-controlled piece of equipment, which may malfunction due to external noise or interference. In this case, set the OPERATE switch to OFF, remove the lithium backup battery, and then set the OPERATE switch to ON again after a few minutes.