9. TIME CODE OPERATION
9-2 Presetting and Recording of Time Code (Cont’d)
TIME CODE PRESETTING PROCEDURE
| 2. HOLD button |
|
| 4. SHIFT button | ||
AUDIO |
|
|
|
| ||
LEVEL |
|
|
|
| ||
|
| |||||
|
|
| ||||
|
|
| AUTO |
| FRONT | |
|
|
| MANUAL |
| REAR | |
|
| AUDIO SELECT |
| AUDIO INPUT | ||
|
| VTR SELECT TC GENE. |
| MENU | ||
SEE |
| INT |
| CONTINUE | ||
INSTR- |
| PRST | REC |
|
| |
UCTION |
| PARA | FREE |
|
| |
| REGEN |
|
| |||
MANUAL |
| EXT |
|
|
| |
| LITHIUM BATT. | CAM AUX | GROUP | ITEM | SELECT | DATA SET |
|
| HOLD | SHIFT | ADVANCE PRESET | ||
|
|
| ||||
|
| VTR INPUT |
|
|
|
|
|
| 3. ADVANCE |
| 6. | ||
|
|
| PRESET | |||
|
|
| button |
| ||
|
|
|
| button | ||
|
|
|
|
|
| |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
|
|
|
|
| HOLD | |
|
| H | M | S |
| F |
1. Display the time code on the counter display. Set the COUNTER switch to "TC".
•Time code up to 23 hrs. 59 min. 59 sec. 29 frames can be preset.
2.Place the time code generator in preset mode. Press the HOLD button.
•The "HOLD" indicator lights on the display to indicate the preset mode. The first digit of the counter display blinks.
3.Set the value of the blinking digit. Press the ADVANCE button.
•The value of the blinking digit changes.
4.Change the blinking digit. Press the SHIFT button.
•The blinking digit changes.
5.Set the desired value for all digits. Repeat steps 3. and 4. for each digit.
6.Preset the set data in the memory. Press the PRESET button.
•The set data is saved as the time code generator value. Following the above operation, the "HOLD" indicator disappears from the display, the counter stops blinking and the time code is preset.
•If the REC/FREE switch is set to FREE, the time code starts to run.
If you preset a wrong time code, perform steps 2. 3. 4. 5. and 6. again.
PRESETTING USER'S BIT DATA
RESET button
| OPERATE/WARNING |
|
|
|
|
|
|
| |
| CH 1 |
|
| OVER | AUTO OFF | DEW | LIGHT | ||
RESET |
|
| ON | ||||||
| 40 30 20 | 10 | 0 dB | SERVO RF | L i | ||||
| CH 2 |
|
| OVER | OFF | ||||
| 32k | 48k | SLAVE | PB | NDF | HOLD |
| ||
MONITOR | AUD LOCK | SP |
|
|
|
|
|
|
|
SELECT | MENU | WIDE | H | M |
| S |
| F | COUNTER |
REMAIN |
| REV FWD | E BATT | F | CTL | ||||
MIX |
| TC | |||||||
|
|
|
|
|
| ||||
| H | M |
|
|
|
|
| UB |
•Pressing the RESET button in the preset mode resets the time code or user's bit data to 00 00 00 00.
•If you press the HOLD button by mistake, press the HOLD button once more to return to the previous display.
Display user's bit data on the counter display and perform the same procedure as the time code presetting procedure.
•The user's bit can be specified using numerals or alphabetic letters from 0 to F for each digit.
Note:
Do not set “F” to all user’s bit, or the data can not be read.
63