| Appendix | |
EZSwitchSetup Limitations | A | |
|
|
|
In this appendix
•General limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
General limitations
Table 3 lists general EZSwitchSetup limitations, which apply to all browsers and switch platforms.
TABLE 3 | EZSwitchSetup Switch Manager limitations | |
|
|
|
Problem Area |
| Details |
|
|
|
HTTP timeout |
| Very often, you may see the following message when you try to get data from a switch or to |
|
| send a request to the switch: |
|
| Failed to get switch response. Please verify the status |
|
| of your last operation and try again if necessary. |
|
| This indicates that an HTTP request did not get a response. The request was sent to the |
|
| switch, but the connection was down, probably caused by a temporary loss of the Web |
|
| server on the switch. Due to the nature of an HTTP connection, Switch Manager will report |
|
| this error after a |
|
| In this case, verify the status of your last request, using Telnet to check related status, or |
|
| click the Refresh button in the Switch Manager to retrieve related data. If your request did |
|
| not get through to the switch, resubmit it. Executing a refresh from Switch Manager |
|
| retrieves a copy of switch data at that moment; the data you entered can be lost if it had |
|
| not already been committed to the switch. |
|
| |
Loss of Connection | Occasionally, you may see the following message when you try to retrieve data from the | |
|
| switch or send a request to the switch: |
Switch Status Checking
The switch is not currently accessible.
The dialog title may vary, because it indicates which module is having the problem.
This is caused by the loss of HTTP connection with the switch, due to a variety of possible problems. Switch Manager automatically tries to regain the connection. While Switch Manager is trying to regain the connection, check if your Ethernet connection is still functioning. If the problem is not with the Ethernet connection, wait for Switch Manager to recover the connection and display the following message:
You will have to resubmit your request after closing this message.
If the temporary switch connection loss is caused by switch hot code load, or other similar operation, the Switch Explorer you are currently running can be downloaded from a different firmware version than the new one. In this case the following message displays: Switch connection is restored. The firmware version you are running is not in sync with the version currently on switch. Close your browser and
You must close Switch Manager and relaunch it to reopen the connection.
EZSwitchSetup Administrator’s Guide | 49 |
|