Connecting devices and completing the setup

2

EZSwitchSetup uses these values to verify that all your current and planned devices are properly connected for the zoning scheme that will be created. Note that Typical Zoning ensures that every connected host device will be able to communicate with every connected storage device.

3.Click Next. The Configure Ports and Connect Devices window is displayed (Figure 16 on page 22).

FIGURE 15 Specify Devices window

Connecting devices and completing the setup

The final step in the switch configuration is to connect your devices to the switch in a way that matches a configured array of connection reservations (HBA or storage) on the ports. In the interactive switch graphic that is displayed on the Configure Ports and Connect Devices window, these connection reservations are shown by the letters H or S against a blue or green background on the ports, and will automatically match the types of the devices that have already been connected, with existing connections shown as green lines that connect the ports with icons representing the devices. If you have indicated on the previous screen that you intend to connect more devices, connection reservations of matching types will also have been made for your planned devices, with dotted blue lines to show you where these devices should be attached. Finally, as you attach the new devices, the dotted blue lines will change to solid green (for correctly attached devices) or to solid red (when devices are attached at ports with non-matching reservations). When a red line appears, the mismatch may be corrected either by moving the device to a different port as suggested by a dotted blue line for a device of that type, or by changing the reservation type of the port where the device is currently connected by clicking on the port icon. In either case, the solid red and dotted blue lines should both disappear, and be replaced by a single solid green line to indicate the correct connection. For connected devices, you can also view details of the device by pausing on the host or storage icon.

The Next button for this screen is not enabled until all non-matching or missing connection issues (indicated by solid red and dotted blue lines) have been resolved.

EZSwitchSetup Administrator’s Guide

21

53-1002744-01

 

Image 31
Contents EZSwitchSetup Brocade Communications Systems, Incorporated Contents Appendix a EZSwitchSetup Limitations How this document is organized This chapterSupported hardware and software Document conventions What’s new in this documentText formatting Corporation Referenced Trademarks and Products Key termsOther industry resources Additional informationGetting technical help Brocade resourcesFT00X0054E9 Document FeedbackEZSwitchSetup Administrator’s Guide Overview of EZSwitchSetup Introducing EZSwitchSetupOperating system Browser JRE version EZSwitchSetup software and hardware requirementsConfiguring Internet Explorer Supported switchesLanguage support for EZSwitchSetup EZSwitchSetup Administrator’s Guide 53-1002744-01 Language support for EZSwitchSetup Installing and running the EZSwitchSetup wizard Setting Up Your SwitchLaunching the EZSwitchSetup wizard EZSwitchSetup introduction window Connecting cablesConnect Cables window Ethernet version, without serial cable Ioioi First Discover Switch window Discovering the switchKeep the current switch IP configuration Confirming IP addresses Installing and running the EZSwitchSetup wizard Click Continue Switch discovery failure Configuring the switch EZSwitchSetup Setup Parameters window Setting switch parametersZoning selection options Specifying devices Configuring zones on the switchSpecify Devices window Connecting devices and completing the setupEZSwitchSetup Administrator’s Guide Ioioi Oioi Connecting devices and completing the setup Connecting devices and completing the setup Switch Manager overview Managing Your SwitchTask panel EZSwitchSetup Switch Manager componentsContent Switch ViewStatus bar Launching the EZSwitchSetup Switch ManagerLogging Switch Manager sessionsLogging out Viewing switch information Viewing fan, temperature, and power supply status Viewing the status indicator legendPort status Port State LEDs Port Information tab Switch Information tabChanging switch information Managing devices Adding a port licenseEZSwitchSetup Administrator’s Guide 53-1002744-01 Detailed Device information Device connectionsDisplay Connections window Assigning and renaming device aliasesDevice aliases moved under Current Aliases Zoning management Device alias in Zone Access MapZone Access Map Viewing the zone access mapEdit HBA/Storage Accessibility Matrix is displayed Editing the zoning configurationZoning management Restoring Typical Zoning Validating zoning configurationMaking EZSwitchSetup your default switch manager Accessing Web Tools for advanced managementGeneral limitations This appendixGeneral limitations Index EZSwitchSetup Administrator’s Guide EZSwitchSetup Administrator’s Guide 53-1002744-01 EZSwitchSetup Administrator’s Guide