Window Blanking menu

ACTIVE

1

2

3 4

Remove unwanted information/noise from the edges of each displayed image by adjusting the blanking. After selecting a window by pressing the Active window selection button (1, 2, 3, or 4), the Window Blanking menu adjusts the top, bottom, left, and right blanking of each output window by rotating the Vertical sizing knob. The selected window number is displayed in the upper right corner of the LCD panel. The window blanking setting is displayed on the bottom of the LCD panel. Press the Next button to advance to the Blanking submenu, or press the Menu button to exit the Window Blanking menu and advance to the Audio Configuration menu.

Blanking submenu

Rotate the Vertical sizing knob to select <Manual> blanking and press the Next button to advance to the Top submenu, or press the Menu button to exit the Blanking submenu and advance to the Audio Configuration menu.

Top submenu

Increase or decrease the Top blanking from 0 to 16 by rotating the Vertical sizing knob until the unwanted information no longer appears. The selected window number (1, 2, 3, or 4), designated by pressing the Active window selection button, is displayed in the upper right corner of the LCD panel. Press the Next button to advance to the Bottom submenu, or press the Menu button to exit the Top submenu and advance to the Audio Configuration menu.

Window

Blanking

Blanking

Auto <Manual>

Top

1 – 4

000 – 016

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom

1 – 4

000 – 016

 

 

 

 

 

 

 

 

 

 

Left

1 – 4

000 – 016

 

 

 

 

 

 

 

 

 

 

Right

1 – 4

000 – 016

Bottom submenu

Increase or decrease the Bottom blanking

from 0 to 16 by rotating the Vertical sizing knob until the unwanted information no longer appears. The selected window number (1, 2, 3, or 4), designated by pressing the Active window selection button, is displayed in the upper right corner of the LCD panel. Press the Next button to advance to the Left submenu, or press the Menu button to exit the Bottom submenu and advance to the Audio Configuration menu.

Left submenu

Increase or decrease the Left blanking from 0 to 16 by rotating the Vertical sizing knob until the unwanted information no longer appears. The selected window number (1, 2, 3, or 4), designated by pressing the Active window selection button, is displayed in the upper right corner of the LCD panel. Press the Next button to advance to the Right submenu, or press the Menu button to exit the Left submenu and advance to the Audio Configuration menu.

MVP 104GX Operation 3-11

Image 29
Contents Multi Video Processor MVP 104GXSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschRack mounting Connecting the MVP 104GXQuick Start MVP 104GX Audio Configuration menu Default Cycle menuAdvanced Configuration menu Position/Size window menuTable of Contents Table of Contents, cont’d One Introduction MVP 104GX FeaturesAbout the MVP 104GX MVP 104GX IntroductionTwo MVP 104GX Installation InstallationRack Mounting Procedure Rear panel of MVP 104GX Rear Panel ConnectorsConnecting the MVP 104GX Installation, cont’dUnbalanced audio Audio input and outputFastening captive screws Balanced audioGenlock connections Setting Up Genlock and Vertical Interval SwitchingGenlock setup Ohm Terminator Superimposed waveforms Oscilloscope displaysVectorscope screen during color subcarrier phase adjustment Three MVP 104GX Operation Front Panel FeaturesOperation MVP 104GX Menu FlowchartInput selection Front Panel OperationFreeze control Audio input selectionFactory patterns User presetsMenu and Next buttons with the LCD panel Active window selectionHorizontal sizing Optimizing the ImageVertical sizing Horizontal positioningTop blanking Rotate the Vertical sizing knob to increase or Default Cycle menu Using the Menu SystemPosition/Size Window menu Product Name submenuContrast submenu Picture Controls menuBrightness submenu Tint submenuBlanking submenu Window Blanking menuTop submenu Bottom submenuAdvanced Configuration menu Audio Configuration menuRight submenu Audio Level submenuWindow Text submenu Window Priority submenuVCR Mode submenu Input Mode submenuSystem Reset submenu Text Style submenuExit menu Genlock menuOperation, cont’d Four Using the Software Installing the Windows-based Control SoftwareWindows-based Control Program MVP 104GX Windows-based Control ProgramWindow adjustment example screen Windows-based Control Program, cont’d Five Programmer’s Guide Remote Control Port RS-232/RS-422Host-to-MVP 104GX Communications MVP 104GX-initiated messagesReconfig Using the command/response tableProgrammer’s Guide, cont’d Freeze Window Audio Channel Gain Command Ascii Example responses to commandsMVP 104GX-generated unsolicited responses MVP 104GX error responsesAAppendix Relocating the ribbon cable and setting the jumper Configuring the MVP 104GX for RS-422Reference Information Removing the top coverMVP 104GX Reference Information A-3 Replacing the top coverSpecifications MVP 104GX MVP 104GX Reference Information A-5 Control/remote video processorGeneral MVP 104GX Reference Information FCC Class a Notice Extron’s Warranty Extron Electronics, USA