Measuring Optical Power
CAUTION: It is important to keep all optical connections and surfaces free from dirt, oils, or other contaminants to ensure proper operation. Always clean all test reference cables before conducting the test procedures outlined in this guide. See “Cleaning Optical Ports” on page 17 for details.
To Measure Optical Power
1.Turn on the FPM 101 power meter by pressing the power button (A).
2.Select the appropriate fiber optic reference cable. The fiber type of this cable must be the same as the fiber type normally connected to the equipment output being measured.
NOTE: Always verify that reference cable loss is not excessive (< 0.5 dB), before
measuring the power output of fiber optic equipment
(see “Testing Fiber Optic Links” on page 12).
3.Select the adapter cap matching the reference cable connector and type.
4.Connect one end of the reference cable to the adapter cap and the other end to the optical output to be measured.
5.Press the wavelength button (E) to select the calibrated wavelength matching the nominal wavelength of the source under measurement.
6.If the power meter is presently measuring insertion loss in dB, press the dB/dBm button (F) to display power in dBm, or press and hold it to display power in μW.
Fiber Optic Equipment
d
c Adapter Cap
|
| 0000 | nm | e | |
|
|
| Hz |
| |
|
|
| ∝W | f | |
|
| 0.00 dB | |||
|
| 0000 | Hz |
| |
|
| nm |
| ||
|
| 0.00 | ∝W |
| |
|
| dB |
| ||
| µW | Set |
|
| |
f | dB | Ref | λ | e | |
dBm | |||||
|
|
|
|
FPM 101
FIBER POWER METER
a
POWER
d
Reference Cable
b
Figure 6. Power Measurement Connections
Fiber Optic Test Meters • Operation 11