11.Connect the receive reference cable to the FPM 101.

12.Connect the free ends of the transmit and receive reference cables together using an appropriate coupler, or use a nearby bulkhead connector.

Transmit Reference

 

 

Receive Reference

Cable

 

Coupler

Cable

 

N

or

N

MM: Mandrel Wrap or

Bulkhead

SM: 1.2 inch (30 mm)

 

 

M

Dia Loop (Shown)

 

 

Do Not Remove

 

 

Adapter Cap

This Connection

 

 

FLS 101

0.4 dB

FPM 101

Figure 9. Connect the Receive Reference Cable

13.Verify the insertion loss of the reference cable pair is less than 0.75 dB, the maximum allowed by the TIA (Extron recommends 0.4 – 0.5 dB).

If the insertion loss (dB) is not within these values:

Disconnect the transmit and receive cables at the coupler (or bulkhead). Clean the free ends of both cables and both sides of the coupler (bulkhead), then repeat step 11 through 13.

If the insertion loss is still not acceptable, replace both test reference cables and begin again with step 1 on page 12.

Insert the Link

1.When the insertion loss is acceptable, (< 0.75 dB), disconnect both the transmit and receive reference cables from the coupler or bulkhead.

NOTE: Do not disturb the reference cable connections at the light source or the power meter.

Fiber Optic Test Meters • Operation 14

Image 20
Contents FPM 101 / FLS Safety Instructions English Conventions Used in this Guide Page Contents Fiber Optic Test Meters Contents Features About this User GuideAbout the FPM 101 and FLS Fiber Optic Test Set offersFLS 101 Light Source offers Power SourceFPM 101 Power Meter offers Accessories FPM 101 Power MeterTypical Applications FLS 101 Light SourceOperation FPM 101 Power Meter Controls and Connections FPM 101 Power MeterDB/dBm/μW Button Power Up the FPMWavelength/Backlight Button Test Mode To Set a Reference Test Mode To View the ReferenceRef/Set Button Splash and Auto-Off ScreenDisplay Readings in Test Mode Field DescriptionFLS 101 Power FLS 101 Light Source Controls and ConnectionsOutput Ports and Indicators Output Wavelength SelectionMeasuring Optical Power To Measure Optical PowerTesting Fiber Optic Links Test the Transmit Reference CableVerify the Reference Cables FLS FPMInsert the Link FLSConnections to Measure Link Insertion Loss Using the Tone Generator To Quickly Identify a Fiber Optic LinkCleaning Optical Ports Cleaning FPM 101 Optical PortsRepair and Calibration Battery ReplacementCleaning FLS 101 Optical Ports Mandrels for Multimode Transmit Reference Cables Loops for Singlemode Transmit Reference CablesOptical specifications- FPM SpecificationsOptical specifications FLS 101 fiber optic output General Included Accessories Page Extron Warranty USA, Canada, South America Japan Central America