Extron electronic manual Power Source, FPM 101 Power Meter offers, FLS 101 Light Source offers

Page 8

The FPM 101 Power Meter offers:

When used with a compatible light source such as the FLS 101, WAVE ID enables the power meter to automatically detect and set wavelengths, simplifying setup.

Power measurements in dBm or μW; insertion loss in dB.

270 Hz, 330 Hz, 1 kHz, 2 kHz tone detection.

The FLS 101 Light Source offers:

Integrated LED and laser light source.

WAVE ID allows a compatible power meter to automatically identify and measure a wavelength.

Dual WAVE ID allows a compatible power meter to automatically identify and measure two wavelengths.

CW mode for use with power meters without WAVE ID.

2 kHz tone for use in fiber tracing or locating.

50 µm and 62.5 µm mandrels included for different diameter fiber cable.

National Institute of Standards and Technology (NIST) traceable.

 

Optical Power Meter

 

 

0000

Hz

 

nm

 

0.00

W

 

dB

WAVE ID

nm

0000

 

 

Hz

 

0.00

W

 

dB

 

 

µW

Set

 

dB

Ref

λ

dBm

 

 

FPM 101

FIBER POWER METER

 

9V

850nm 1300nm

1310nm 1550nm

 

FLS 101

 

FIBER LIGHT SOURCE

CW

CW

850nm

1310nm

1300nm

1550nm

 

Tone

Figure 1. FPM 101 Power Meter and FLS 101 Laser Source

Power Source

The units each operate on two AA alkaline or rechargeable batteries each.

NOTE: If the battery level becomes too low, each unit turns itself off.

Fiber Optic Test Meters • Introduction

2

Image 8
Contents FPM 101 / FLS Safety Instructions English Conventions Used in this Guide Page Contents Fiber Optic Test Meters Contents Features About this User GuideAbout the FPM 101 and FLS Fiber Optic Test Set offersFLS 101 Light Source offers Power SourceFPM 101 Power Meter offers Accessories FPM 101 Power MeterTypical Applications FLS 101 Light SourceOperation FPM 101 Power Meter Controls and Connections FPM 101 Power MeterDB/dBm/μW Button Power Up the FPMWavelength/Backlight Button Test Mode To Set a Reference Test Mode To View the ReferenceRef/Set Button Splash and Auto-Off ScreenDisplay Readings in Test Mode Field DescriptionFLS 101 Power FLS 101 Light Source Controls and ConnectionsOutput Ports and Indicators Output Wavelength SelectionMeasuring Optical Power To Measure Optical PowerTesting Fiber Optic Links Test the Transmit Reference CableVerify the Reference Cables FLS FPMInsert the Link FLSConnections to Measure Link Insertion Loss Using the Tone Generator To Quickly Identify a Fiber Optic LinkCleaning Optical Ports Cleaning FPM 101 Optical PortsRepair and Calibration Battery ReplacementCleaning FLS 101 Optical Ports Mandrels for Multimode Transmit Reference Cables Loops for Singlemode Transmit Reference CablesOptical specifications- FPM SpecificationsOptical specifications FLS 101 fiber optic output General Included Accessories Page Extron Warranty USA, Canada, South America Japan Central America