Extron electronic FPM 101 Specifications, Optical specifications FLS 101 fiber optic output

Page 26

Reference

Material

This section provides technical specifications, included and replacement part numbers, and optional accessories.

Specifications

Included Accessories

Specifications

NOTE: These devices are class 1 laser products. They meet the safety regulations of IEC-60825,

FDA 21 CFR 1040.10, and FDA 21 CFR 1040.11.

Optical specifications — FLS 101 fiber optic output

Number/type

 

Singlemode

1 laser emitter

Multimode

1 LED emitter

Connectors

2 connectors with LC, SC FC, and ST adapters

Wavelengths

 

Singlemode

1310 nm ±20 nm, 1550 nm ±20 nm

Multimode

850 nm ±30 nm, 1310 nm -10/+50 nm

Spectral width

 

Singlemode

5 nm (max.) at 1310 nm and at 1550 nm

Multimode

40 nm (typical) at 850 nm

 

120 nm (typical) at 1310 nm

Transmission power

 

Singlemode

0 dBm, 9 µm

Multimode

-20 dBm, 62.5 µm

NOTE: Power will be 3 dB lower if a 50 µm mandrel-wrapped jumper is used instead of a 62.5 µm mandrel-

wrapped jumper.

Stability

 

Singlemode

±0.05 dB over 1 hour after 15 minute warmup

 

±0.1 dB over 8 hours after 15 minute warmup

Multimode

±0.1 dB over 8 hours after 5 minute warmup

Optical specifications— FPM 101

Wavelengths

850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm; calibrated

Detector type

Germanium (Ge)

Units of measurement

dB, dBm, µW

Fiber Optic Test Meters • Reference 20

Image 26
Contents FPM 101 / FLS Safety Instructions English Conventions Used in this Guide Page Contents Fiber Optic Test Meters Contents About the FPM 101 and FLS FeaturesAbout this User Guide Fiber Optic Test Set offersFLS 101 Light Source offers Power SourceFPM 101 Power Meter offers Typical Applications AccessoriesFPM 101 Power Meter FLS 101 Light SourceOperation FPM 101 Power Meter Controls and Connections FPM 101 Power MeterDB/dBm/μW Button Power Up the FPMWavelength/Backlight Button Ref/Set Button Test Mode To Set a ReferenceTest Mode To View the Reference Splash and Auto-Off ScreenDisplay Readings in Test Mode Field DescriptionFLS 101 Power FLS 101 Light Source Controls and ConnectionsOutput Ports and Indicators Output Wavelength SelectionMeasuring Optical Power To Measure Optical PowerTesting Fiber Optic Links Test the Transmit Reference CableVerify the Reference Cables FLS FPMInsert the Link FLSConnections to Measure Link Insertion Loss Using the Tone Generator To Quickly Identify a Fiber Optic LinkCleaning Optical Ports Cleaning FPM 101 Optical PortsRepair and Calibration Battery ReplacementCleaning FLS 101 Optical Ports Mandrels for Multimode Transmit Reference Cables Loops for Singlemode Transmit Reference CablesOptical specifications- FPM SpecificationsOptical specifications FLS 101 fiber optic output General Included Accessories Page Extron Warranty USA, Canada, South America Japan Central America