Using the command/response tables
The command/response tables on the next page list valid command ASCII codes, the MLS’s responses to the host, and a description of the command’s function or the results of executing the command. Upper- and
ASCII to HEX Conversion Table |
| The ASCII to hexadecimal |
|
| (HEX) conversion table at left |
| • | is for use with the |
|
| |
|
| command/response tables. |
ASCII to Hex conversion table |
|
|
Symbol definitions
] = CR/LF (carriage return/line feed) (hex 0D 0A)
•= Space
E = | Escape key | ||
X! = Specific input number (0 – 6 maximum) | |||
|
| 0 | = no connection |
|
| 1 | = input 1 |
|
| 2 | = input 2 |
|
| 3 | = input 3 |
|
| ... |
|
|
| 6 | = input 6 |
X@ | = | Maximum number of input channels | |
|
| (1 – 4 [max.] for the MLS 304 Series or 1 – 6 [max.] | |
|
|
| for the MLS 406 Series) |
X# | = | Video type (can be set for inputs 3 – 4 of the MLS 304 | |
|
| Series or inputs 4 – 6 of the MLS 406 Series only) | |
|
| 1 | = Vid (composite video [MLS 304 Series only] |
|
|
| and/or S‑video [MLS 406 Series only]) |
|
| 2 | = RGB (default) |
X$ | = | Audio gain | |
|
| (0 dB through +24 dB in 1 dB steps) | |
|
| (default = 0 dB for MLS 304MA, MLS 406, | |
|
| MLS 406MA; default = +6 dB for MLS 304SA, | |
|
| MLS 406SA) | |
X% | = | Audio attenuation (1 to 42; 0 dB through | |
|
|
| 1 dB steps) |
X^ | = | On/off status | |
|
| 0 | = off/disable |
|
| 1 | = on/enable |
X& | = | Input to be adjusted (1 – 4 for MLS 304 Series, 1 – 6 for | |
|
| MLS 406 Series switchers) | |
|
| 1 | = input 1 |
|
| 2 | = input 2 |
|
| 3 | = input 3 |
|
| ... |
|
|
| 6 | = input 6 |
X( = Adjustment range (0 – 14)
1.5dB steps) 0 =
7 = +0 dB (default)
8 = +1.5 dB
9 = +3.0 dB
10 = +4.5 dB
11 = +6.0 dB
12 = +7.5 dB
13 = +9.0 dB
14 = +10.5 dB
X1) = Volume adjustment range (0 – 100 steps)
X1! = Switcher firmware version (listed to two decimal places e.g.: x.xx)
X1@ = Executive mode (front panel lockout) status 0 = unlocked (default)
1 = front panel except volume adjustment is locked
PRELIMINARY
MLS 304 Series, MLS 406Series• Serial Communication | 4- |