Extron electronic MLS 304MA, MLS 304SA, MLS 406SA, MLS 406MA That has an external power supply

Page 16

Installation, cont’d

RS-232

MLC/IR

TxRx IR +12V

A B C

MediaLink

 

Switcher

 

rear panel

Tx Rx IR 12V

 

RS-232

RS-232/MLC/IR port

MLC/IR

A B C

MediaLink Switcher Rear Panel

NOTE

If using an external power

 

 

supply (instead of the MLS) to

MediaLink

 

power the MLC, you must

Controller

 

connect a ground wire

(MLC)

 

between the MLC and MLS.

 

 

 

 

 

Ground (

 

)

 

Transmit (Tx) B

 

Ground (

 

)

 

 

 

 

 

B Receive (Rx)

 

 

 

 

 

 

 

 

 

 

 

 

A Transmit (Tx)

 

Receive (Rx) A

 

+12 VDC input

External

Power Supply

PRELIMINARY

NOTE If you use cable that has a

 

MLC

 

 

drain wire, tie the drain wire

MLS/Power

External

 

to ground at both ends.

A B

port

Power Supply

 

 

 

(12 VDC, 1A max.)

 

 

MLS / Power

 

 

 

MediaLink Switcher to an MLC

Ground all devices

 

that has an external power supply

 

RS-232

 

 

 

 

MLC/IR

MediaLink

 

 

 

TxRx IR +12V

Switcher

 

 

 

 

rear panel

 

 

Tx Rx IR 12V

 

 

 

 

RS-232

A B C

RS-232/MLC/IR port

 

 

MLC/IR

 

 

A B C

 

 

 

MediaLink Switcher Rear Panel

 

NOTE Connect a ground wire between the MLC and the computer or control system.

Ground ( )

 

 

or

B Receive (Rx)

Transmit (Tx) 3

 

 

A Transmit (Tx)

Receive (Rx) 2

 

 

NOTE If you use cable that has a

Host Computer

Control System

RS-232 port

 

drain wire, tie the drain wire

of a

 

to ground at both ends.

computer or

 

 

 

control system

 

MediaLink Switcher to a computer or control system

You may use a male 9-pin D-to-bare-wire RS‑232 cable or a universal control cable (UC 50', UC 100', or UC 200') for the connection to a computer or control system. One end of the UC cable is terminated with a female 9-pin D connector, and the other end is unterminated. The UC cable’s pin assignments are as shown in the following illustration. Refer to the computer/control system’s pin assignment guide to determine which of the cable’s wires to connect to which of the MLS’s RS‑232/MLC/IR port pins.

 

Black

9

 

 

 

 

 

 

Grey

8

 

 

 

 

To the

To the

Purple

7

 

 

1

 

Blue

6

 

 

6

computer

MLS

Green

5

 

 

 

or

 

 

 

9

switcher

Yellow

4

 

UC Cable

5

control

 

Orange

3

 

 

 

system

 

Red

2

 

 

 

 

 

 

 

 

 

 

 

Brown

1

Shield

 

Connector Shell

 

 

 

 

 

 

 

 

 

Color

Pin #

 

 

 

 

 

 

 

 

 

 

UC 50', 100', 200' Cable Color Codes

2- MLS 304 Series, MLS 406 Series • Installation

Image 16
Contents MediaLink Switchers MLS 304MA, MLS 304SA, MLS 406, MLS 406MA, MLS 406SAPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschInstallation Quick Start MLS 304MA, MLS 406, MLS 406MAVideo Configuration Table of Contents Table of Contents, cont’d One Features IntroductionAbout this Manual About the MLS 304 Series and the MLS 406 SeriesTwo Installation UL/Safety RequirementsImportant Safety Instructions MLS 304 Series, MLS 406 Series InstallationTabletop use Mounting the SwitcherRack mounting Power, input, and control connections Power connectionMLS 304 Series, MLS 406 Series Installation Rear Panels and CablingInput Type Signal BNC Color Balanced Mono InputInstallation, cont’d  MLS 304 Series, MLS 406 Series InstallationIR Link IR signal repeater Control connectionThat has an external power supply Video outputs Video output, local monitor, and audio output connectionsAudio outputs Unbalanced Mono Output Balanced Mono Output Wiring for 4 ohm or 8 ohm speakers MA models Ohm Total LoadSpeakers Tapped at 7.5 Watts Each Equals 15 Watts Total Wiring for 4 ohm or 8 ohm speakers SA models Stereo OutputSpeaker arrangement examples Examples of speaker layoutsMLC Application DiagramsExtron MLC ProjectorThree Operation and Setup Front Panel Features and Operation MLS 304 Series, MLS 406 Series Operation and Setup Minimum threshold at least 21%MLS 304 Series, MLS 406 Series Operation and Setup Front panel security lockout executive modesResetting the switcher Setting Up and Optimizing the AudioMLS 304 Series, MLS 406 Series Operation and Setup Configuring Lineout and Preamp output levels Adjusting audio input levelsMaking adjustments Signal detection thresholdClipping level Normal rangeVideo Signal Routing Standard mode modeDA distribution amplifier mode mode RGB follow mode modeMode Selected input Input special conditions Monitor Output Remote ControlMode If the switcher does not respond to controls TroubleshootingIf the image does not appear or there is no sound Preliminary Four RS-232 Programmer’s Guide Serial CommunicationHost-to-MLS communications Symbol definitions Using the command/response tablesMLS 304 Series, MLS 406Series Serial Communication Command/response table for SIS commands Command Ascii Command Response Additional descriptionAudio status for the active input Aux/Mix inputFirmware version, part number & information requests Command/response table for special function SIS commands Command Ascii Command Response ? valuesUsing the control program Installing the softwareControl Software for Windows User Mode Screen Special featuresSwitcher MLS Config Screen Preliminary File menu options Saving and restoring configurationsUpdating firmware Follow the on-screen instructions Key to file names Using the help programFile name Description AAppendix a Specifications Reference MaterialVideo Video input and loop-throughAudio SyncMLS 304 Series, MLS 406 Series Reference Material A- Audio output mono power amp MLS 304MA, MLS 406MA only Audio inputAudio output Lineout and Preamp Included partsControl/remote switcher Audio output stereo power amp MLS 304SA, MLS 406SA onlyGeneral Part Numbers and Accessories Optional accessoriesIncluded parts Replacement Part number Accessory Part numberFrequency Response Graph for the Loudness Feature Audio Reference LevelsAudio Block Diagrams MLS 304MA audio block diagramMLS 304SA audio block diagram Utinpse LE CTMLS 406, MLS 406MA audio block diagram InputsMLS 406SA audio block diagram MLS 304 Series, MLS 406 Series Reference Material A-11This page was deliberately left blank FCC Class a Notice Extron’s Warranty Extron Electronics, USA