Quick Installation Checklist

…… Determine which rooms will have IP Intercoms and HelpDesk PCs and where, in each room, they will be located. Ensure there is a network connection for each intercom and each HelpDesk PC.

For the IPI 100 Series models

…… Connect the IPI to the MLC 226 IP controller, using the included 12 inch (30.5 cm) network cable (see page 2-2).

…… Cable the MLC 226 IP to other devices:

Connect the LAN port to the local network, using a standard network cable with an RJ-45 connector.

If desired, cable the rear panel audio connector for local audio output (see page 2-2).

Cable other devices (control modules, SCP, and/or IR emitters) to the MLC as needed (for more information, see the MLC 226 IP User’s Manual, which is available on the Extron website (www.extron.com).

…… Install the IPI 100 unit and the MLC 226 IP into the wall box(es) or furniture (see page C-2).

…… Ensure the HelpDesk PC(s) is connected to the network and power it on.

…… Configure the MLC(s) as described in the MLC 226 IP User’s Manual and the Global Configurator Help File, which are available on the Extron website (www.extron.com).

For the IPI 200 Series models

…… Connect the LAN port to the local network, using a standard network cable, with an RJ-45 connector (see page 2-3).

…… Connect power, and, if required, contact relay and local audio output, using the rear panel captive screw connectors (see page 2-3).

…… Mount each IPI 200 into furniture, an AAP wallplate, mounting bracket for 2-gang wallplates, or device faceplate. The AAP versions must be secured by attaching a clamp bracket to the back of the intercom after it has been inserted through the front of the AAP plate (see page C-3).

…… Ensure the HelpDesk PC(s) is connected to the network and power it on.

For all models

…… Install the Extron IP Intercom HelpDesk software, which is on the disk that shipped with the unit and is also available for download from the Extron website (www.extron.com).

…… Use the IP Intercom HelpDesk software to configure all intercom units in the system (see chapter 5). Full instructions can be found in the software’s Help File.

When the front panel button(s) light amber, the unit is correctly installed and configured. If the button(s) light red the unit has not been correctly configured and you should check the IPI 100 Series and IPI 200 Series User’s Manual or the software’s Help File.

Extron USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500 +1.714.491.1517 FAX

Extron USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794 +1.919.863.1797 FAX

Extron Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040 +31.33.453.4050 FAX

Extron Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400 +65.6383.4664 FAX

Extron Japan

+81.3.3511.7655 +81.3.3511.7656 FAX

Extron China

+400.883.1568

Inside China Only

+86.21.3760.1568 +86.21.3760.1566 FAX

Extron Middle East

+971.4.2991800 +971.4.2991880 FAX

© 2009 Extron Electronics. All rights reserved.

Image 86
Contents MediaLink IP Intercom Interfaces Push to TalkConsignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschFCC Class a Notice Page Table of Contents Table of Contents, cont’d IPI 100 and IPI 200 Series Table of Contents Iii Iv IPI 100 and IPI 200 Series Table of Contents One Before you get StartedAbout this Manual Terms and symbols used in this manualPreface IPI 101 AAP IPI 104 AAP IPI 201 Series IPI 204 SeriesAbout the IP Intercom Modules Additional reference materialLED indicator to show when the room is being monitored FeaturesSecurity features System Requirements UL RequirementsPreface, cont’d Installlation TwoMLC 226 IP’s rear panel, as shown in the following figure InstalllationIPI 100 and IPI 200 Series Installation Connector MLC 226 IP AAP or a mounting frameInstalllation, cont’d MLC Audio ConnectionSample Applications Single PC to panelMultiple PCs to panel NetworkPanel-to-panel mode Server mode Intercom with amplifier MPAInstalllation, cont’d Three OperationIPI 100 and IPI 200 Series Operation Front Panel Features and OperationOperation Indication lighting\⤀ Button OperationPush to talk operation Button Color IndicationOperation Initial Configuration FourBefore you Begin Initial ConfigurationIPI 100 and IPI 200 Series Initial Configuration IPI 200 Series intercom unit must be Setting the IP address using Global ConfiguratorAt its factory default IP address Advanced button name changes to BasicIntercom unit’s embedded Web page is displayed Setting the IP address using embedded Web pagesOpen a Web browser on the local PC Return to the TCP/IP Properties dialog box on the PC Setting the IP address using the ARP command Arp s IP address MAC addressFive HelpDesk SoftwareIntroduction to the Software Installling the SoftwareHelpDesk Software IPI 100 and IPI 200 Series HelpDesk SoftwareLog-in as User Log-in as a HelpDesk Administrator Starting the ProgramHelpDesk Software, cont’d Using the Configuration Utility Configuring the IP Intercom SystemBasic Configuration Use the drop-down menu to select the appropriate optionEntering an IP address manuallly Importing a GC2/GCZ fileClick Import. a Windows Open dialog box opens Select Manually by IP Address from the drop-down menuScanning the local subnet Configuring an IP device with the configuration utility Talk mode Listen mode Start speaking. WhileGroup announcement Select an available group or All IntercomsTo load a pre-recorded file Loading a pre-recorded .wav fileChanging the default .wav file for intercom events Setting up a peer-to-peer network Calll forwardingAll HelpDesks must be linked to the Server PC None of the PCs can be set to Server ModeSetting up one PC as a server Server PC must be set to Server Mode HelpDesk Software, cont’d Specifications, Part Numbers Accessories Specifications, Part Numbers, Accessories Specifications IPI 100 SeriesIncluded Parts IPI 100 Series\⤀ Accessories IPI 100 Series\⤀Accessories Part number Included parts Replacement Part numberSpecifications, Part Numbers, Accessories, cont’d Specifications IPI 200 SeriesExtron Lbs 0.2 kg Amplifiers, cable, miscelllany Part number Accessories IPI 200 Series\⤀Included Parts IPI 200 Series\⤀ Specifications, Part Numbers, Accessories, cont’d AppendixBB SIS Programming and ControlIPI-initiated Messages SIS Programming and ControlHost-to-IPI Communications IPI 100 and IPI 200 Series SIS Programming and ControlError response references Password informationError responses Commands and Reponses Using the command/response tableTelnet Web Browser Symbol definitions= On/off status 0 = off / disable 1 = on /enable = Escape key hex 1B Use W instead of Esc for Web browsersX4! = X4 = = on, disable/lock the front panel X7! =+X20 Command/response table for SIS commandsX20 X1! X1! X1!  Command Ascii Telnet\⤀ URL Encoded ResponseX1! C X1! X1@ or  X1@ CN Ipn X1@ IpnX4  X4 X1$  X3$  X1$ CI X1* Bmd X6$,X1$  X2@  X6$,X1$ EB   X6$ EB X5@ or  X3# CU  IpuX4! CK  Pvl X5@ Directory commands Stream Files via Telnet or RS-232IPI 100 and IPI 200 Series SIS Programming and Control B-15 File handling commandsStream Files via Port 1AE 0AEReset zap\⤀/Erase Commands IPI 100 and IPI 200 Series SIS Programming and Control B-17SIS Programming and Control, cont’d AppendixCC MountingIPI 100 and IPI 200 Series Mounting MountingMounting the IPI 100 Series Mounting the IPI 200 Series Mounting, cont’d Button Labels IPI 100 and IPI 200 SeriesDAppendix DButton Labels Installling or Replacing Button LabelsInstallling the Button-Label Generator software Button Label Generator softwareUsing the Button-Label Generator software Installling Button Labels TextExtron Warranty Quick Installation Checklist
Related manuals
Manual 2 pages 44.12 Kb