Sync
Standards....................................... NTSC 3.58, NTSC 4.43, PAL, SECAM
Control/remote — switcher
Serial control port | 1 |
Baud rate and protocol | 9600 baud, 8 data bits, 1 stop bit, no parity |
Serial control pin configurations | 1 = TX, 2 = RX, 3 = GND |
Contact closure | (1) 3.5 mm captive screw connector, 5 pole |
Contact closure pin configurations . 1 = input 1, 2 = input 2, 3 = input 3, 4 = input 4, 5 = GND | |
Program control | Extron Universal Switcher program for Windows |
| Extron Simple Instruction Set (SIS) |
General |
|
External power supply | 100 VAC to 240 VAC, |
Power input requirements | 12 VDC, 0.2 A |
Cooling | Convection, no vents |
Temperature/humidity | Storage: |
| Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
Mounting |
|
Rack mount | Yes, with optional 1U rack shelf |
Furniture mount | Yes, with optional mini |
Enclosure type | Metal |
Enclosure dimensions | 1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide) |
| (4.3 cm H x 10.9 cm W x 6.5 cm D) |
| (Depth excludes connectors.) |
Product weight | 0.6 lbs (0.3 kg) |
Shipping weight | 3 lbs (2 kg) |
Vibration | ISTA 1A in carton (International Safe Transit Association) |
Regulatory compliance |
|
Safety | CE, |
EMI/EMC | CE, |
MTBF | 30,000 hours |
Warranty | 3 years parts and labor |
NOTE: All nominal levels are at ±10%.
NOTE: Specifications are subject to change without notice.
MSW 4V rs and MSW 4SV rs • Specifications | 16 |