Extron electronic DMS 1600 Accessing the Html Pages, Configuring for Network Communication

Page 18

4.If you selected IP [LAN] in step 2, the IP Connection window appears.

Figure 12. IP Connection Window

a.Examine the Matrix IP Address field, which displays the last Matrix IP address entered.

If necessary, enter the correct IP address in the field.

NOTE: 192.168.254.254 is the factory-specified default value for this field.

b.If the switcher is password-protected, enter the appropriate administrator or user password in the Password field.

c.Click Connect. The Matrix Switchers Control Program is ready for operation.

Accessing the HTML Pages

Another way to configure and operate the switcher is via its factory-installed HTML pages, which are always available and cannot be erased or overwritten. The HTML pages that are pre-loaded on the switcher are accessible through its LAN port, connected via a LAN or WAN, using a web browser such as Microsoft® Internet Explorer® (see item F on page 8, for connection information.)

Configuring for Network Communication

The first time you connect a PC to the LAN port of a switcher, you may need to temporarily change the IP settings of the PC in order to communicate with the controller. Then you must change the default settings of the controller (IP address, subnet mask, and [optional] administrator name and password) in order to use the unit on an intranet (LAN) or on the Internet. After you have set up the DMS matrix switcher for network communication, you can reset the PC to its original network configuration.

NOTE: The computer and the switcher must both be connected to the same subnet on a LAN (using a straight-through cable). Alternatively, you can use a crossover Ethernet cable to connect the controller directly to the computer.

Use the ARP command to configure the IP address as follows:

1.Obtain a valid IP address for the DMS matrix switcher from the network administrator.

2.Obtain the MAC address (UID #) of the switcher from the label on its rear panel. The MAC address should have this format:

00-05-A6-xx-xx-xx.

3.If the switcher has never been configured and is still set for factory defaults, go to step 4. If not, perform a mode 4 system reset. For detailed information on reset modes, see “Reset Operations” in the DMS Series Matrix Switchers User Guide.

NOTE: The switcher must be configured with the factory default IP address (192.168.254.254) before the ARP command is executed, as described below.

4.At the PC, access the MS-DOS®command prompt, then enter the arp–scommand. Type in the desired new IP address for the unit (see step 1) and the MAC address of the unit (from the rear panel of the unit). For example (where the new address is 10.13.197.7): arp–s 10.13.197.7 00-05-A6-03-69-B0and then press <Enter>.

After receiving the arp -s command, the controller changes to the new address and starts responding to the ping requests, as described in step 5.

NOTE: You must ping the DMS matrix switcher as shown in step 5 for the IP address change to take place. The response should show the new IP address, as shown in the following figure.

24 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control

DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 25

Image 18
Contents DMS 1600, DMS DMS 3200, DMS Safety Instructions FCC Class a NoticeFDA/IEC 60825-1 Requirements Contents Introduction About this GuideAbout the DMS Matrix Switchers ConfigurabilityConfigurability rules Installation Board Configuration OverviewRear Panel DMS 1600 Features Making ConnectionsPrimary and Redundant Power Supply LEDs DMS 1600 and DMS Front PanelComputer or control system connection Use a crossover cable Front Panel Operations Creating a TieViewing Ties and Muting Outputs Locking Out the Front Panel Executive Mode Remote ControlSaving or Recalling a Preset Selected SIS CommandsNumber of connections Host-to-Switcher InstructionsCommon SIS Command Symbols Establishing a USB Port ConnectionCommand and Response Table for SIS Commands Create ties# Edid values # value for DMS model Resolution # Edid values # value for DMS model Source1024x768 @ 60 Hz Channel mute commands Save and recall presetsInformation requests Command and Response Table for IP-Specific SIS Commands IP and serial port setupInstalling and Starting the Control Program Installing the ProgramFirst-time Connection Considerations Starting the ProgramAccessing the Html Pages Configuring for Network CommunicationLoading the Start-up Downloaded Start-upMaintenance Modifications Removing and Installing an I/O Board or Blank PanelRemove and Install an I/O Board Removing and Installing a Fan DMS 1600 and DMS Remove and Install a FanPage Extron Warranty Extron India