ERemote port — If desired, connect a control system or computer to the rear panel Remote RS-232/RS-422 port.

 

 

Pin RS-232 Function

RS-422 Function

 

 

1

Not used

Not used

5

1

2

Tx

Transmit

Tx–

Transmit (–)

3

Rx

Receive

Rx–

Receive (–)

 

 

4

Not used

Not used

 

 

5

Gnd

Ground

Gnd

Ground

9

6

6

Not used

Not used

7

Not used

Rx+

Receive (+)

 

 

 

 

8

Not used

Tx+

Transmit (+)

 

 

9

Not used

Not used

Figure 7. Remote RS-232/RS-422 Output Connector Wiring

FEthernet port (LAN connector) — If desired, connect a network WAN or LAN hub, a control system, or a computer to the Ethernet RJ-45 port.

Network connection — Use a patch (straight-through) cable.

Computer or control system connection — Use a crossover cable.

NOTE: The factory default IP address is 192.168.254.254.

GReset button — Initiates four levels of reset of the matrix switcher. For different reset levels, press and hold the recessed button while the switcher is running or while you power up the switcher.

See the DMS Series Matrix Switcher User Guide, available on the Extron DVD or at www.extron.com.

HPower connectors — Plug the switcher into one or two (depending on the DMS model) grounded AC sources.

NOTE: For reliability in switchers with Primary and Redundant power supplies, connect the power cord from the Redundant power connector to either an uninterruptible power source or to a power source that is completely independent of the primary power source.

IPrimary and Redundant power supply indicator LEDs (DMS 1600 and DMS 3600)

Green — Indicates that the associated power supply is operating within normal tolerances.

Red — Indicates that the associated power supply is operating outside the normal tolerances or has failed (see Removing and Installing a Power Supply Module (DMS 1600 and DMS 3600) on page 31 to replace the power supply).

JFans (DMS 1600 and DMS 3600) — See Removing and Installing a Fan (DMS 1600 and DMS 3600) on page 32.

Front Panel

 

 

CONTROL

 

 

 

 

CONFIG

ENTER

PRESET

VIEW

ESC

 

CONTROL

 

 

 

 

 

 

 

 

 

PRIMARY

 

 

ENTER

VIEW

ESC

 

 

CONFIG

PRESET

 

REDUNDANT

POWER

POWER SUPPLY

 

DMS 1600

 

DMS 2000

 

TMDS DIGITAL MATRIX SWITCHER

 

 

 

 

TMDS DIGITAL MATRIX SWITCHER

1

2

1

3

Figure 8. Front Panel Features

AConfiguration port — If desired, connect a control system or computer to the front panel Configuration port, a mini USB B port.

BPrimary and Redundant Power Supply LEDs (DMS 1600 and DMS 3600) —

NOTE: The meaning of these indicators is identical to the LEDs on the power supplies (item I, on the previous page).

Green — Indicates that the associated power supply is operating within normal tolerances.

Red — Indicates that the associated power supply is operating outside the normal tolerances or has failed (see Removing and Installing a Power Supply Module (DMS 1600 and DMS 3600) on page 31 to replace the power supply).

CPower LED (DMS 2000 and DMS 3200)— Indicates that the power supply is operating within normal tolerances.

NOTE: The power supply is fixed, and not field replaceable, on the DMS 2000 and DMS 3200.

8 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation

DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 9

Image 8
Contents DMS 1600, DMS DMS 3200, DMS FDA/IEC 60825-1 Requirements Safety InstructionsFCC Class a Notice Contents Introduction About this GuideConfigurability rules About the DMS Matrix SwitchersConfigurability Rear Panel InstallationBoard Configuration Overview DMS 1600 Features Making ConnectionsComputer or control system connection Use a crossover cable Primary and Redundant Power Supply LEDs DMS 1600 and DMSFront Panel Viewing Ties and Muting Outputs Front Panel OperationsCreating a Tie Remote Control Saving or Recalling a PresetLocking Out the Front Panel Executive Mode Selected SIS CommandsHost-to-Switcher Instructions Common SIS Command SymbolsNumber of connections Establishing a USB Port ConnectionCommand and Response Table for SIS Commands Create ties1024x768 @ 60 Hz # Edid values # value for DMS model Resolution# Edid values # value for DMS model Source Information requests Channel mute commandsSave and recall presets Command and Response Table for IP-Specific SIS Commands IP and serial port setupInstalling and Starting the Control Program Installing the ProgramFirst-time Connection Considerations Starting the ProgramAccessing the Html Pages Configuring for Network CommunicationLoading the Start-up Downloaded Start-upMaintenance Modifications Removing and Installing an I/O Board or Blank PanelRemove and Install an I/O Board Removing and Installing a Fan DMS 1600 and DMS Remove and Install a FanPage Extron Warranty Extron India

DMS 3200, DMS 3600, DMS 1600, DMS 2000 specifications

Extron Electronics has long been a leader in the field of audio-visual integration, and their DMS family of switchers showcases their commitment to quality and innovation. The DMS 2000, DMS 1600, DMS 3600, and DMS 3200 are modular AV switching solutions designed to meet the needs of various AV applications, enhancing flexibility and functionality in managing signals.

The DMS 2000 is known for its exceptional ability to support a wide range of input and output configurations, making it suitable for various environments, from classrooms to corporate boardrooms. One of its main features is its modular construction, allowing users to customize the unit with different input and output cards based on the specific requirements of a project. This flexibility is coupled with Extron's exceptional scaling technology, which ensures high-quality video signal processing across diverse sources.

The DMS 1600, though smaller in capacity, still offers impressive features aimed at efficient signal management. This model can handle multiple HDMI inputs and outputs, positioning it well for smaller AV setups or as a stepping stone for upgrading existing systems. Its built-in EDID and HDCP management simplify integration with modern display devices, making it easier for users to connect multiple sources without worrying about compatibility issues.

Meanwhile, the DMS 3600 brings enhanced capabilities, boasting higher capacities suitable for larger installations. This model supports extensive audio routing options and extensive control capabilities, making it ideal for complex AV systems where seamless integration is critical. The advanced control options include support for various control systems, allowing users to integrate the DMS 3600 with existing technology seamlessly.

Lastly, the DMS 3200 offers features that are particularly appealing for installations that require both AV signal management and advanced control functionalities. Its robust processing capabilities ensure that it can handle high-resolution video signals with minimal latency. Additionally, the DMS 3200 excels in audio capabilities, supporting various audio formats and providing a comprehensive audio management system.

Overall, the DMS family of products from Extron Electronics stands out due to their modularity, advanced scaling technologies, and exceptional signal management capabilities. These characteristics make them ideal for a diverse range of applications, from educational environments to corporate settings, where flexibility and high performance are paramount. Their commitment to innovation and quality continues to position Extron Electronics at the forefront of AV technology.