Extron electronic DMS 2000, DMS 3600 First-time Connection Considerations, Starting the Program

Page 17

4.Follow the on-screen instructions. The installation program creates a C:\Program Files\Extron\Matrix_Switchers directory and an “Extron Electronics\Matrix Switchers” group folder. It installs the following four programs:

MATRIX Switcher+ Control Program

MATRIX Switcher+ Help

Uninstall MATRIX Switcher

Check for Matrix Updates

First-time Connection Considerations

LAN port connection

If you connect your PC to the switcher via the LAN port, and it is the first time you have done so, you may change the default settings (IP address, subnet mask, and [optional] administrator password) on the controller (see Configuring for Network Communication on page 25 for details.)

USB port connection

When you connect your PC to the DMS matrix switcher via the USB port for the first time, the Found New Hardware Wizard opens.

1

1

Activate the connected USB port for your device as follows:

NOTE: If you have not installed the latest Matrix Switchers Control Program, click Cancel and install the program. Reconnect the switcher to the Configuration port.

1.Select the No, not this time radio button and click Next. The wizard installs the necessary driver to access the switcher via the Configuration (USB) port (this may take a few minutes).

2.On the next page that appears, select the Install the software automatically radio button and click Next. Follow the on-screen

instructions. The wizard assigns the driver necessary to access the switcher to the connected Configuration (USB) port (this may take a few minutes).

3.Click Finish to exit the wizard.

NOTE: You may need to repeat these steps if you subsequently connect the switcher to a different USB port on the same computer.

Starting the Program

1.Click Start > Programs > Extron Electronics > Matrix Switchers > MATRIX Switcher + Control Pgm.

The Comm Port Selection window appears.

Figure 11. Comm Port selection Window

2.Choose the comm (serial) port that is connected to the switcher, USB, or IP [LAN].

NOTE: For a comm port, check the baud rate displayed in the Comm Port Selection window. If you need to change the baud rate, click the Baud button and double-click the desired baud rate.

3.Click OK.

If you selected a serial port or the USB port in step 2, the Matrix Switchers Control Program is ready for operation.

22 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control

DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 23

Image 17
Contents DMS 1600, DMS DMS 3200, DMS FDA/IEC 60825-1 Requirements Safety InstructionsFCC Class a Notice Contents About this Guide IntroductionConfigurability rules About the DMS Matrix SwitchersConfigurability Rear Panel InstallationBoard Configuration Overview Making Connections DMS 1600 FeaturesComputer or control system connection Use a crossover cable Primary and Redundant Power Supply LEDs DMS 1600 and DMSFront Panel Viewing Ties and Muting Outputs Front Panel OperationsCreating a Tie Saving or Recalling a Preset Remote ControlLocking Out the Front Panel Executive Mode Selected SIS CommandsCommon SIS Command Symbols Host-to-Switcher InstructionsNumber of connections Establishing a USB Port ConnectionCreate ties Command and Response Table for SIS Commands1024x768 @ 60 Hz # Edid values # value for DMS model Resolution# Edid values # value for DMS model Source Information requests Channel mute commandsSave and recall presets IP and serial port setup Command and Response Table for IP-Specific SIS CommandsInstalling the Program Installing and Starting the Control ProgramStarting the Program First-time Connection ConsiderationsConfiguring for Network Communication Accessing the Html PagesDownloaded Start-up Loading the Start-upRemoving and Installing an I/O Board or Blank Panel Maintenance ModificationsRemove and Install an I/O Board Remove and Install a Fan Removing and Installing a Fan DMS 1600 and DMSPage Extron Warranty Extron India

DMS 3200, DMS 3600, DMS 1600, DMS 2000 specifications

Extron Electronics has long been a leader in the field of audio-visual integration, and their DMS family of switchers showcases their commitment to quality and innovation. The DMS 2000, DMS 1600, DMS 3600, and DMS 3200 are modular AV switching solutions designed to meet the needs of various AV applications, enhancing flexibility and functionality in managing signals.

The DMS 2000 is known for its exceptional ability to support a wide range of input and output configurations, making it suitable for various environments, from classrooms to corporate boardrooms. One of its main features is its modular construction, allowing users to customize the unit with different input and output cards based on the specific requirements of a project. This flexibility is coupled with Extron's exceptional scaling technology, which ensures high-quality video signal processing across diverse sources.

The DMS 1600, though smaller in capacity, still offers impressive features aimed at efficient signal management. This model can handle multiple HDMI inputs and outputs, positioning it well for smaller AV setups or as a stepping stone for upgrading existing systems. Its built-in EDID and HDCP management simplify integration with modern display devices, making it easier for users to connect multiple sources without worrying about compatibility issues.

Meanwhile, the DMS 3600 brings enhanced capabilities, boasting higher capacities suitable for larger installations. This model supports extensive audio routing options and extensive control capabilities, making it ideal for complex AV systems where seamless integration is critical. The advanced control options include support for various control systems, allowing users to integrate the DMS 3600 with existing technology seamlessly.

Lastly, the DMS 3200 offers features that are particularly appealing for installations that require both AV signal management and advanced control functionalities. Its robust processing capabilities ensure that it can handle high-resolution video signals with minimal latency. Additionally, the DMS 3200 excels in audio capabilities, supporting various audio formats and providing a comprehensive audio management system.

Overall, the DMS family of products from Extron Electronics stands out due to their modularity, advanced scaling technologies, and exceptional signal management capabilities. These characteristics make them ideal for a diverse range of applications, from educational environments to corporate settings, where flexibility and high performance are paramount. Their commitment to innovation and quality continues to position Extron Electronics at the forefront of AV technology.