Installation
Installation Overview
To install and set up the SW2/SW4 switcher,
1Mount the switcher on a rack shelf or furniture, if desired.
2Connect input source(s) to one or more SW2/SW4 video input connectors.
3Connect an output device to the SW2/SW4 output connector.
4Connect the audio connectors of your input device(s) to the SW2/SW4 audio input 3.5 mm TRS mini jacks.
5Wire one of the provided
6Insert the other provided captive screw plug into the
7If using autoswitching,
8If necessary, wire the provided
9Power on the output display.
10Apply power to the switcher.
11Power on the input device(s).
Mounting the SW DVI A Series
The SW DVI A Series switcher can be set on a table, mounted on a rack shelf, or mounted under a desk, podium, or table.
Tabletop use
Four
Rack mounting
For optional rack mounting, do not install the rubber feet. Mount the switcher on any of the following rack shelves:
•RSB 123 1U, 3.5" Deep VersaTools® Basic Rack Shelf (part
•RSF 123 1U, 3.5" Deep VersaTools Rack Shelf Kit (part
•RSB 126 1U, 6" Deep Basic Rack Shelf (part
•RSU 126 1U, 6" Deep Universal Rack Shelf Kit (part
•RSB 129 1U, 9.5" Deep Basic Rack Shelf (part
•RSU 129 1U, 9.5" Deep Universal Rack Shelf Kit (part
•MBB 100 VersaTools Back of the Rack Mounting Kit (part
UL rack mounting guidelines
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the equipment in a rack.
1. Elevated operating ambient temperature — If the equipment is installed in a closed or
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised.
3. Mechanical loading — Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading.
4. Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
5. Reliable earthing (grounding) — Maintain reliable grounding of
SW DVI A Series • Installation | SW DVI A Series • Installation |