Black Box AC455A-TX-R2, AC456A-RX-R2 manual Electrical, Environmental, Mechanical

Page 10

FIBER LINK

Electrical

Input Voltage—AC455A-TX-R2: 12 to 16 VAC, 12 to 14 VDC; AC456A-RX-R2: 13.5 to 16 VDC

Input Power Frequency—50 to 60 Hz

Current Requirement—AC455A-TX-R2: 300 mA; AC456A-RX-R2: 380 mA

Power Consumption—6 W

Heat Equivalent—0.3 BTU/min., 0.09 cal/min.

NOTE

The heat equivalent represents the conversion of all input power to heat. The actual heat generated will be less.

Environmental

Temperature—Operating: 32 to 122°F (0 to 50°C); Storage: -40 to +185°F (-40 to +85°C)

Mechanical

Enclosure—Transmitter: 4 x 4 (10 x 10 cm); Receiver: 501R

Construction—Aluminum enclosure with black semigloss paint finish

Mounting Method—(4) No. 6 (3-mm) screws

Size—AC455A-TX-R2: 1.2"H x 4.6"W x 4.7"D (3 x 11.7 x 11.9 cm), including connectors; AC456A-RX-R2: 1.2"H x 6.3"W x 9.8"D (3.2 x 16.2 x 24.9 cm), including connectors

Weight—AC455A-TX-R2: 0.7 lb. (0.3 kg); AC456A-RX-R2: 1.6 lb. (0.7 kg)

9

Image 10
Contents Fiber Link-Transmitter Fiber Link-Receiver Fiber Link Fiber Link Fiber Link Trademarks Used in this Manual Contents Video Signal SpecificationsVideo Interconnection Genlock Sync Signal Control Data SignalOptical Controls ConnectorsAgency Compliance LEDsEnvironmental ElectricalMechanical Introduction Additional FeaturesDescription Typical Application Installation Physical InstallationSignal Connections Standalone TransmitterPower Connections Optical ConnectionsSystem Power ALARM/+5VDC GroundTransmitter and Receiver Optical Indicators Indicator Display What It MeansFiber Link End View of Standalone Module Try This First TroubleshootingCalling Black Box Shipping and Packaging Copyright 2001. Black Box Corporation. All rights reserved