Receiver Launch Power—>-14 dBm (850 nm)
Agency Compliance
Emissions—FCC Part 15; ICES-003 (Canada); AS/NZS 3548 (Australia/NZ); CE EN55022; CE EN50082-1, including EN61000-4-2 ESD, EN61000-4-3 Radiated Immunity, EN61000-4-4 Electrical Fast, Transient Burst (EFT) Immunity, EN61000-4-5 Power Surge Immunity, EN61000-4-6 Conducted Disturbances Immunity, EN61000-4-11 Voltage Dips, Short Interruptions and Voltage Variations
Immunity—ENV50204 Radiated, Pulsed Magnetic Field Immunity
Product Safety—No standards required, since the Fiber Link is DC-powered by SELV (Safety Extra-Low Voltage)
Controls
Alarm Disable—Removable jumper on receiver cards
LEDs
Video In (bicolor)—Shows presence of good video signal
Level/Loss (bicolor)—Shows presence of good optical signal
COMMAND—Shows activity on PTZ control channel
RESPONSE—Shows activity on response channel
SYNC—Shows activity on genlock channel
Connectors
Signal Input—Optical: ST®; Video: BNC
Signal Output—Optical: ST; Video: BNC
Power Input—Standalone units: 3-pin detachable screw terminal connector; Rack units: Direct rack connection