Tripp Lite APS 612 owner manual APS Location Warnings

Page 4

Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite APS Systems.

APS Location Warnings

Install your APS indoors, away from excess moisture or heat, dust or direct sunlight.

Your APS is NOT waterproof. Contact with water can cause the unit to short circuit and could cause personal injury due to electric shock. Never immerse your APS. Mount it in the driest location available.

Leave adequate space around all sides of the APS for proper ventilation.The heavier the load of connected equipment, the more heat will be generated by the APS.

Do not install the APS near magnetic storage media, as this may result in data corruption.

Battery Connection Warnings

Your APS will not operate with or without utility power until batteries are connected.

Multiple battery systems must be made up of batteries of the same voltage, age, amp hour capacity and type.

Keep battery location well ventilated. Explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated.

Sparks may result during final battery connection.Always observe proper polarity as batteries are connected.

Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious injury to property or person could result.

Equipment Connection Warnings

Do not use Tripp Lite APS Systems in life support applications where a malfunction or failure of a Tripp Lite APS System could cause failure or significantly alter the performance of a life support device.

Do not alter the cord of your APS in a way that would eliminate its connection to ground. Do not use adapters that would eliminate the APS’s connection to ground. Connect the input cord of your APS to a properly grounded, 3-wire, 120V 60 Hz power receptacle. Do not plug your APS into itself; this may damage the unit and will void your warranty.

Do not connect a surge suppressor, line conditioner or UPS to the output of the APS.

Operation Warnings

Your APS does not require routine maintenance. Do not open your APS for any rea- son.There are no user-serviceable parts inside.

Potentially lethal voltages exist within this unit as long as the battery supply and/or AC input are connected. During any service work, the battery supply and AC input cord should therefore be disconnected.

Do not connect or disconnect batteries while the APS is operating from the battery supply. Dangerous arcing may result.

4

Image 4
Contents APS 612 PowerVerter Introduction High Efficiency OutputStage Battery Charger APS Location Warnings Configuration DIP SwitchesSelecting Battery Type Battery SelectionSelecting Battery Amp Hour Capacity Battery Connection DC Ground ConnectionSet Operating Mode Switch AC ConnectionAC Input Electrical Connection AC Output Electrical ConnectionSwitches Switches, Indicator Lights & Other FeaturesIndicator Lights Other Features Maintenance & Service Limited WarrantyMaintenance ServiceSymptom Problems Corrections Two symbols are used on the APS labels AC Voltage DC Voltage Manual de Operación Introducción Salida de Alta EficienciaProtección Automática contra Sobrecargas Luces Indicadoras de Funciones MúltiplesIntroducción continua Cargador Avanzado De 3 Etapas para BateríasInversor con Salida de Frecuencia Controlada Tarjetas de Circuitos ProtegidasPrecauciones Sobre la Ubicación del APS Precauciones Sobre la Conexión de BateríasPrecauciones Sobre la Conexión de Equipos Precauciones de OperaciónConfiguración Interruptores DIPSeleccione el Tipo de Baterías Interruptor DIP No Seleccione el Punto Bajo de Voltaje de CASeleccione la Capacidad en Amperios/Hora de las Baterías Selección de BateríasSeleccione el Tipo de Baterías Conexión de Baterías Conexión de CD a TierraRegule el Interruptor Operating Mode Modo de Operación Conexión de CAConexión de la Entrada Eléctrica de CA Conexión de la Salida Eléctrica de CAInterruptores Interruptores, Luces Indicadoras y Otras CaracterísticasLuces Indicadoras Otras Características Línea Encendida INV EncendidoMantenimiento Garantía LimitadaServicio Resolucion de Problemas Simtoma Problemas SolucionNota sobre el etiquetado InversorDiagrams/Esquemas Battery HI/MED/LO