Tripp Lite SMART1200XLHG, AGSM1200PSR3HG, AGSM700PSR3HG, SMART700HG, BP36V27 Storage & Service

Page 10

Basic Operation continued

NORM DELAY

Power Sensitivity Adjustment (Select Models Only): This dial is normally set fully counterclockwise, which enables the UPS to pro- tect against waveform distortions in its AC input. When such distor- tion occurs, the UPS will normally switch to providing PWM sine wave power from its battery reserves for as long as the distortion is present. In areas with poor utility power or where the UPS’s input power comes from a backup generator, chronic waveform distortion could cause the UPS to switch to battery too frequently, draining its battery reserves. You may be able to reduce how often your UPS switches to battery due to waveform distortion by experiment- ing with different settings for this dial. As the dial is turned clock- wise, the UPS becomes more tolerant of variations in its input power’s AC waveform. NOTE: The further the dial is adjusted clock- wise, the greater the degree of waveform distortion the UPS will allow to pass to connected equipment. When experimenting with dif- ferent settings for this dial, operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS’s output can be evaluated without disrupting critical oper-

Storage & Service

Storage

For SmartPro Models Only: CAUTION! Your UPS has an internal power source. Its outlets may still deliver current, even after the UPS is unplugged, until the UPS is completely turned OFF (deactivated). Before storing your UPS, turn it completely OFF: with the UPS ON and receiving utility power, press and hold the POWER button for one second (an alarm will beep once briefly after the interval has passed); then, unplug the UPS from the wall outlet. If you store your UPS for an extended period of time, recharge the UPS batteries once every three months: plug the UPS into a wall outlet; allow it to charge for 12 hours; and then unplug it and place it back in storage. Note: after you plug the UPS in, it will automatically begin charging its batteries; however, it will not supply power to its outlets (see Quick Installation section). If you leave your UPS batteries discharged for an extended period of time, they will suffer a permanent loss of capacity.

For OmniSmart Models Only: All connected equipment should be turned off, then disconnected from the UPS to avoid battery drain. Unplug your UPS from its AC receptacle. CAUTION: Your UPS has an internal power source. Its outlets may still deliver current after it is unplugged, until the UPS is deactivated. To deactivate the UPS, press and hold its UPS/STANDBY button. Your UPS is now ready for storage. If you plan on storing your UPS for an extended period of time, fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 12 hours. If you leave your UPS batteries discharged for an extended period of time, they will suffer a permanent loss of capacity.

10

Image 10
Contents UPS Systems with Medical Grade UPS SystemsHospital-Grade Plugs Receptacles Important Safety Instructions UPS Location WarningsFor OmniSmart Models Only USB Communications Quick Installation optionalSerial Communications Tel/DSL ProtectionButtons For SmartPro Models Only-POWER ButtonFor OmniSmart Models Only-UPS/STANDBY Button For All Models-MUTE/TEST Button Indicator Lights Power LEDBattery Charge / Battery Power LED Other UPS Features Storage Service OMNISMART350HG SMART700HG SMART1200XLHG Sistemas UPS con Sistemas UPS grado médicoEnchufes y receptáculos grado hospital Advertencias sobre la conexión del equipo Importantes instrucciones de seguridadAdvertencias sobre la colocación del UPS Advertencias sobre las bateríasPara todos los modelos-Conecte su equipo en el UPS Sólo para modelos SmartProSólo para modelos OmniSmart Sólo para modelos SmartPro Encienda el UPSProtección para módem / fax Instalación rápida optativaComunicaciones en serie Baterías externasBotones Sólo para modelos SmartPro- Botón Power Alimentación Sólo para modelos OmniSmart-Botón UPS/STANDBY UPS/ReservaOperación básica continuación Para todos los modelos-Botón MUTE/TEST Silencio/PruebaLuces indicadoras Operación básica continuación Otras características del sistema UPS Almacenamiento Servicio Nota sobre el rotulado Système UPS de classe médicale Système UPS avec fiche UL1778 et prises de classe hôpitalMises en garde relatives au raccord du système UPS Mises en garde relatives à lemplacement du système UPSImportantes consignes de sécurité Mises en garde relatives au raccord de léquipementPour les modèles OmniSmart uniquement Pour les modèles SmartPro uniquementPour tous les modèles-Branchez votre équipement dans lUPS Protection du modem télécopieur Installation rapide facultativeCommunications en série Batteries externesExploitation de base Exploitation de base suite Pour tous les modèles-bouton MUTE/TEST MUET/TESTVoyants lumineux Exploitation de base suite Autres fonctions Entreposage Entretien Capacité de sortie VA/Watts200310034

OMNISMART350HG, BP36V27, AGOM350KSR57HG, SMART1200XLHG, SMART700HG specifications

Tripp Lite is a renowned manufacturer of power protection and connectivity solutions, and its lineup includes various high-quality products designed to meet the diverse needs of users. Among its offerings are the AGSM700PSR3HG, BP36V27, AGOM350KSR57HG, SMART1200XLHG, and OMNISMART350HG, each designed with unique features and technologies to ensure reliability and efficiency.

The AGSM700PSR3HG is a versatile sine wave uninterruptible power supply (UPS) designed for both home and office environments. With a robust 700VA/500W capacity, it provides battery backup and surge protection to critical devices. Its advanced microprocessor control technology guarantees accuracy and fast response to power disturbances. The UPS features multiple NEMA outlets, ensuring compatibility with various devices. Additionally, it includes USB connectivity for easy monitoring and management via Tripp Lite’s software.

The BP36V27 is an external battery pack that provides extended runtime for compatible Tripp Lite UPS systems. With a 36V battery configuration and high-quality battery technology, it increases the overall battery life of connected devices, ensuring operation during extended power outages. This feature is especially valuable for organizations that require uninterrupted operation of critical systems.

For high-demand environments, the AGOM350KSR57HG is an advanced line-interactive UPS. Featuring a 350VA/300W capacity, it combines automatic voltage regulation with surge protection to safeguard sensitive electronics from power fluctuations. Its compact design allows for easy installation in tight spaces, while a user-friendly LCD interface provides real-time status updates on power conditions and battery health.

The SMART1200XLHG is another robust UPS solution, offering 1200VA/1000W capacity and pure sine wave output. It is particularly suitable for networking equipment, PCs, and other electronics that require clean and consistent power. The unit features a high-efficiency design that optimizes energy usage and minimizes heat output, contributing to a greener environment.

Lastly, the OMNISMART350HG is an economical UPS that provides essential power backup and surge protection. With a capacity of 350VA/200W, it is designed for use with smaller devices, such as routers and modems. Its compact form factor makes it ideal for home offices or small businesses, and it also includes an easy-to-read LED display for monitoring power status.

In summary, Tripp Lite's AGSM700PSR3HG, BP36V27, AGOM350KSR57HG, SMART1200XLHG, and OMNISMART350HG offer outstanding features, technologies, and characteristics tailored to protect valuable equipment from power disturbances while providing peace of mind during outages. Whether for personal use or business applications, these products exemplify dependability in power management solutions.