Tripp Lite 200310080, 93-2182 owner manual Operation, Switch Modes, Indicator Lights

Page 5

Operation

Switch Modes

After configuring, mounting and connecting your Inverter/Charger, you are able to operate it by switching between the following oper- ating modes as appropriate to your situation:

AUTO/REMOTE: Switch to this mode when you need constant, uninterrupted AC power for connected appliances and equipment. The Inverter/Charger will continue to supplyAC power to connected equipment and

to charge your connected batteries while utility- or generator-suppliedAC power is present. Since the inverter

is ON (but in Standby) in this mode, it will automatically switch to your battery system to supply AC power to connected equipment in the absence of a utility/generator source or in over/under voltage sit- uations. “AUTO/REMOTE” also enables an optional remote control module (Tripp Lite model APSRM2, sold separately or included with select models) to function when connected to the unit.

LOAD Red Indicator: This red light will ILLUMI- NATE CONTINUOUSLY whenever the inverter is functioning and the power demanded by connected appliances and equipment exceeds 100% of load capacity. The light will BLINK to alert you when the inverter shuts down due to a severe overload or overheating. If this happens, turn the operating mode switch “OFF”; remove the over- load and let the unit cool. You may then turn the operating mode switch to either “AUTO/REMOTE” or “CHARGE ONLY” after it has adequately cooled. This light will be off when AC power is supplying the load.

BATTERY Indicator Lights: These three lights will illuminate in several sequences to show the approximate charge level of your con- nected battery bank and alert you to two fault conditions:

Approximate Battery Charge Level*

CHARGE ONLY: Switch to this mode when you are not using connected appliances and equipment in

order to conserve battery power by disabling the inverter. The Inverter/Charger will continue to supply AC power to connected equipment and charge con-

nected batteries while utility- or generator-supplied AC power is present. However, since the inverter is OFF in this mode, it WILL NOT supply AC power to connected equipment in the absence of a utility/generator source or in over/under voltage situations.

OFF: Switch to this mode to shut down the Inverter/Charger completely, preventing the inverter from drawing power from the batteries, and prevent-

 

 

Battery Lights

Battery Capacity

 

 

Illuminated

(Charging/Discharging)

 

 

 

Green

91%–Full

1

 

 

 

Green & Yellow

81%–90%

2

 

 

 

Yellow

61%–80%

3

 

 

 

Yellow & Red

41%–60%

4

 

 

 

Red

21%–40%

5

 

 

 

All three lights off

1%–20%

6

 

 

 

Flashing red

0% (Inverter

7

 

 

 

 

shutdown)

1

2

3

4

5

6

7

 

 

ing utility AC from passing through to connected equipment or charging the batteries. Use this switch to automatically reset the unit if it shuts down due to overload or overheating. First remove the excessive load or allow the unit to suf- ficiently cool (applicable to your situation). Switch to “OFF”, then back to “AUTO/REMOTE” or “CHARGE ONLY” as desired. If unit fails to reset, remove more load or allow unit to cool further and retry. Use an optional remote control module (Tripp Lite model APSRM2, sold separately or included with select models) to reset unit due to overload and overtemperature.

*Charge levels listed are approximate. Actual conditions vary depending on battery condition and load.

Fault Condition

 

 

 

 

Battery Lights

Fault

 

 

 

Illuminated

Condition

 

 

1

All three lights

Excessive discharge

 

 

 

flash slowly*

(Inverter shutdown)

1

2

2

All three lights

Overcharge (Charger

 

 

 

flash quickly**

shutdown)

 

 

Indicator Lights

Your Inverter/Charger (as well as an optional Tripp Lite Remote Control Module, sold separately or included with select models) is equipped with a simple, intuitive, user-friendly set of indicator lights. These easily-remembered “traffic light” signals will allow you, shortly after first use, to tell at a glance the charge condition of your batteries, as well as ascertain operating details and fault conditions.

LINE Green Indicator: If the operating mode switch is set to “AUTO/REMOTE”, this light will ILLUMINATE CONTINUOUSLY when your con- nected equipment is receiving continuous AC power supplied from a utility/generator source.

If the operating mode switch is set to “CHARGE

ONLY”, this light will BLINK to alert you that the unit’s inverter is OFF and will NOT supply AC power in the absence of a utility/gen- erator source or in over/under voltage situations.

INV (Inverting) Yellow Indicator: This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery-supplied, inverted AC

power (in the absence of a utility/generator source or in over/under voltage situations). This light will be off

when AC power is supplying the load. This light will BLINK to alert you if

theloadis less than the Battery Charge Conserver (Load Sense) setting.

5R

*Approximately ½ second on, ½ second off. See Troubleshooting section. ** Approximately ¼ second on, ¼ second off. May also indicate a battery charger fault exists. See Troubleshooting section.

Resetting Your Inverter/Charger to Restore AC Power

Your Inverter/Charger may cease supplying AC power or DC charg- ing power in order to protect itself from overload or to protect your electrical system. To restore normal functioning:

Overload Reset: Switch operating mode switch to “OFF” and

remove some of the connected electrical load (ie: turn off some of the AC devices drawing power which may have caused the overload of the unit). Wait one minute, then switch operating mode switch back to either “AUTO/REMOTE” or “CHARGE ONLY.”

Output Circuit Breaker Reset: Alternatively, check output circuit breaker(s) on the unit's front panel. If tripped, remove some of the elec- trical load, then wait one minute to allow components to cool before resetting the circuit breaker. See Troubleshooting for other possible reasons AC output may be absent.

Image 5
Contents RV Series v DC-to-AC Inverter/Chargers ContentsLimited Warranty SpecificationsBattery Connection Warnings Important Safety InstructionsLocation Warnings Equipment Connection Warnings16 † Feature IdentificationIndicator Lights Switch ModesResetting Your Inverter/Charger to Restore AC Power OperationSet Configuration DIP Switches ConfigurationGroup a DIP Switches All Models Group B DIP Switches Not on 612 ModelsAll Models, except RV612UL & RV612ULH Select Auxiliary Battery Type if any Battery SelectionVehicular and Non-Vehicular Horizontal Mount MountingVehicular Battery ConnectionConnection for Models with Cords and Receptacles AC Input/Output ConnectionTroubleshooting ServiceMaintenance

200310080, 93-2182 specifications

Tripp Lite, a renowned leader in power protection and connectivity solutions, designs high-quality products tailored to meet the demands of businesses and individuals alike. Among their extensive catalog is the Tripp Lite 93-2182,200310080 model, a powerhouse of technological innovation and pragmatic design.

The Tripp Lite 93-2182 is a versatile power distribution unit (PDU) that is engineered to provide efficient and reliable power to multiple devices. With a rack-mountable design, it is ideal for data centers, server rooms, and any setup where space is at a premium. Its sleek form factor allows it to blend seamlessly into existing infrastructure while maximizing power delivery and minimizing clutter.

One of the standout features of this PDU is its combination of multiple output options, including various NEMA outlets to accommodate a wide range of devices. This makes it an excellent solution for environments with diverse equipment requirements. Users can connect servers, networking equipment, and other critical devices without the need for additional power strips, promoting a cleaner workspace and reduced risk of tripping hazards.

In terms of technology, the Tripp Lite 93-2182 is equipped with surge protection capabilities that shield connected equipment from voltage spikes. This protection is crucial in safeguarding sensitive electronics from potential damage. Additionally, the PDU features built-in circuit breakers which provide over-current protection, ensuring the safe operation of connected devices.

Another significant characteristic of this model is its robust monitoring capabilities. Some versions come with options to monitor power consumption, which can help users make informed decisions regarding load balancing and energy efficiency. Furthermore, comprehensive management features allow for efficient remote monitoring, enhancing control over power distribution across the network.

The durability of the Tripp Lite 93-2182 is also noteworthy. Constructed with high-quality materials, it is designed to withstand the rigors of a dynamic data environment. The attention to detail in its design ensures that it operates under various conditions while maintaining optimal performance.

In summary, the Tripp Lite 93-2182,200310080 represents a culmination of advanced engineering and practical design. With its versatile output options, surge protection features, and robust monitoring capabilities, it is a reliable choice for anyone looking to optimize their power distribution needs, particularly in tight spaces where efficiency is paramount.