Tripp Lite 200310080, 93-2182 owner manual All Models, except RV612UL & RV612ULH

Page 7
B4 B3 B2 B1
B4 B3 B2 B1
B4 B3 B2 B1

Configuration (continued)

All Models, except RV612UL & RV612ULH*

Select Battery Charger-Limiting Points—OPTIONAL (Not on 612 Models)

“Most Limiting” (#B2 & #B1 Up): Charger-limiting takes effect the moment any 120V AC load is applied; charger out- put falls gradually from full output at no 120V load passing through to no output at full load.

All Models, except RV612UL, RV612ULH & RV1012UL*

“Least Limiting” (#B2 Down & #B1 Up, factory setting for all models except

RV1012UL): Charger-limiting begins when the Inverter/Charger’s load reaches

66% of the Inverter/Charger’s load rating. Charger output falls gradually from full

output at 66% of the Inverter/Charger’s load rating to about 40% of full output at full load.

“No Limiting” (#B2 & #B1 Down): No

“Less Limiting” (#B2 Up & #B1 Down, factory setting for RV1012UL models): Charger-limiting begins when the Inverter/Charger’s load reaches 33% of the Inverter/Charger’s load rating. Charger output falls gradually from full output at 33% of the Inverter/Charger’s load rating to about 40% of full output at full load.

charger-limiting occurs at any load size.

B4 B3 B2 B1

*NOTE! RV612UL & RV612ULH models do not include these DIP Switches. There are only two limiting points available for RV1012UL models—"Most Limiting" and "Less Limiting"—which are determined solely by the position of the B1 DIP Switch (either up or down). The B2 DIP Switch on these models has no affect.

B3

Select Equalize Battery Charge—OPTIONAL

 

 

 

 

 

 

 

 

 

Setting Procedure

 

 

 

(Not on 612 Models)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Move to “Equalize” (DOWN) position for three seconds.

This DIP Switch is momentarily engaged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B4

 

B3

 

B2

 

B1

Reset

 

Move to “Reset” (UP) position and leave it there. This is the

to begin the process of equalizing the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

factory default setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

charge state of your battery’s cells by time-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: Do not leave DIP switch #B3 in the down position after beginning process. Battery

limited overcharge of all cells. This can

 

 

 

 

 

 

 

 

 

 

 

 

 

Equalize

 

charge equalization should only be performed in strict accordance with the battery manufacturer’s

extend the useful life of certain types of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

instructions and specifications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

batteries; consult with your battery’s manufacturer to determine if

Battery Charge

Switch Position

 

your batteries could benefit from this process. The charge equaliza-

Reset

Up (factory setting)

 

tion process is automatic; once started, it can only be stopped by

removing the input power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equalize

Down—momentarily

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Charger

Switch Position

B4

Set Battery Charging Amps—OPTIONAL (function included

 

on

A4

switch on 612 models)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Charge Amps

Up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check specifications for your unit’s high- and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Charge Amps

Down (factory setting)

low-charging amp options. By setting on

 

 

 

B4

 

B3

 

B2

 

B1

 

 

 

 

 

 

 

 

 

 

high charging, your batteries will charge at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: When switching to the High Charge Amp setting, the user must ensure that the

maximum speed and your RV 12V DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amp hour capacity of their battery system exceeds the amperage of the High Charge Amp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system loads will be well-supplied. When

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting or the batteries may be damaged or degraded.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting on low charging, you lengthen the life of your batteries (especially smaller ones).

Set Battery Charge Conserver (Load Sense) Dial—OPTIONAL (Not on 612 models)

In order to save battery power, the unit’s inverter automatically shuts off in the absence of any power demand from connected equipment or appliances (the electrical load). When the unit detects a load, it automatically turns its inverter function on. Users may choose the minimum load the Inverter/Charger will detect by adjusting the Battery Charge Conserver Dial (see diagram). Using a small tool, turn the dial clockwise to lower the minimum load that will be detected, causing the inverter to turn on for smaller loads. When the dial is turned fully clockwise, the inverter will operate even when there is no load. Turn the dial counter- clockwise to increase the minimum load that will be detected, causing the inverter to stay off until the new minimum load is reached.

Note: the factory setting for the dial is fully clockwise. However, based on the threshold load to which you’d like the inverter to respond, you should adjust the dial counterclockwise to reduce its sensi- tivity until the inverter is active only when connected equipment or appliances are actually in use.

Connect Remote Control—OPTIONAL (All models)

All models feature an 8-conductor telephone style receptacle on the front panel for use with an optional remote control module (Tripp Lite model APSRM2, sold separately or included with select models). The remote module allows the Inverter/Charger to be mounted in a compartment or cabinet out of sight, while operated conveniently from within the living area or control panel of your RV. See instructions packed with the remote control module.

Connect Battery Temperature Sensing Cable—OPTIONAL (not on 612 models)

The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature. Connect the sensor cable (the cable, included with select models, has an RJ style connector on one end and a black sensor on the other) to the RJ style jack located on the side of the Inverter/Charger labeled “Remote Temp. Sense.” Affix the sensor to the side of your battery below the electrolyte level. To guard against false readings due to ambient temperature, place the sensor between batteries, if possible, or away from sources of extreme heat or cold. If the sensor cable is not used, the Inverter/Charger will charge according to its default 25º C values.

Utilize Automatic Generator Starter Capability—OPTIONAL (not on 612 models)

All models except 612 models include an RJ type modular jack on the side panel labeled “Generator Start”. Attach to vehicle generator ON/OFF switching mechanism with user-supplied cable (see Pin Configuration Diagram). Once attached, the interface will allow the Inverter/Charger to automatically switch a vehicle generator on when connected bat- tery voltage levels are low (11.6 VDC) and switch it off when battery voltage levels are high (14.1 VDC).

1

2

3

4

5

6

Pin Configuration

2 - Common

3 - N.C.

(Normally Closed)

4 - N.O.

(Normally Open)

7R

Image 7
Contents RV Series v DC-to-AC Inverter/Chargers ContentsLimited Warranty SpecificationsEquipment Connection Warnings Important Safety InstructionsBattery Connection Warnings Location Warnings16 † Feature IdentificationOperation Switch ModesIndicator Lights Resetting Your Inverter/Charger to Restore AC PowerGroup B DIP Switches Not on 612 Models ConfigurationSet Configuration DIP Switches Group a DIP Switches All ModelsAll Models, except RV612UL & RV612ULH Select Auxiliary Battery Type if any Battery SelectionVehicular and Non-Vehicular Horizontal Mount MountingVehicular Battery ConnectionConnection for Models with Cords and Receptacles AC Input/Output ConnectionMaintenance ServiceTroubleshooting

200310080, 93-2182 specifications

Tripp Lite, a renowned leader in power protection and connectivity solutions, designs high-quality products tailored to meet the demands of businesses and individuals alike. Among their extensive catalog is the Tripp Lite 93-2182,200310080 model, a powerhouse of technological innovation and pragmatic design.

The Tripp Lite 93-2182 is a versatile power distribution unit (PDU) that is engineered to provide efficient and reliable power to multiple devices. With a rack-mountable design, it is ideal for data centers, server rooms, and any setup where space is at a premium. Its sleek form factor allows it to blend seamlessly into existing infrastructure while maximizing power delivery and minimizing clutter.

One of the standout features of this PDU is its combination of multiple output options, including various NEMA outlets to accommodate a wide range of devices. This makes it an excellent solution for environments with diverse equipment requirements. Users can connect servers, networking equipment, and other critical devices without the need for additional power strips, promoting a cleaner workspace and reduced risk of tripping hazards.

In terms of technology, the Tripp Lite 93-2182 is equipped with surge protection capabilities that shield connected equipment from voltage spikes. This protection is crucial in safeguarding sensitive electronics from potential damage. Additionally, the PDU features built-in circuit breakers which provide over-current protection, ensuring the safe operation of connected devices.

Another significant characteristic of this model is its robust monitoring capabilities. Some versions come with options to monitor power consumption, which can help users make informed decisions regarding load balancing and energy efficiency. Furthermore, comprehensive management features allow for efficient remote monitoring, enhancing control over power distribution across the network.

The durability of the Tripp Lite 93-2182 is also noteworthy. Constructed with high-quality materials, it is designed to withstand the rigors of a dynamic data environment. The attention to detail in its design ensures that it operates under various conditions while maintaining optimal performance.

In summary, the Tripp Lite 93-2182,200310080 represents a culmination of advanced engineering and practical design. With its versatile output options, surge protection features, and robust monitoring capabilities, it is a reliable choice for anyone looking to optimize their power distribution needs, particularly in tight spaces where efficiency is paramount.