Moxa Technologies EDS-508 user manual VLANs and Moxa EtherDevice Switch, Management Vlan

Page 52

EDS-508 Series User’s Manual

Featured Functions

specify that the new port is on VLAN Marketing. You do not need to carry out any re-cabling.

#VLANs provide extra security: Devices within each VLAN can only communicate with other devices on the same VLAN. If a device on VLAN Marketing needs to communicate with devices on VLAN Finance, the traffic must pass through a routing device or Layer 3 Switch.

#VLANs help to control traffic: With traditional networks, congestion can be caused by broadcast traffic that is directed to all network devices whether they require it or not. VLANs increase the efficiency of your network because each VLAN can be set up to contain only those devices that need to communicate with each other.

VLANs and MOXA EtherDevice Switch

Your EDS provides support for VLANs using the IEEE Std 802.1Q-1998. This standard allows traffic from multiple VLANs to be carried across one physical link. The IEEE Std 802.1Q-1998 allows each port on your EDS to be placed in:

#Any one VLAN defined on the EDS.

#Several VLANs at the same time using 802.1Q tagging.

The standard requires that you define the 802.1Q VLAN ID about each VLAN on your EDS before the Switch can use it to forward traffic:

The Management VLAN

A new or initialized EDS contains a single VLAN—the Default VLAN. This VLAN has the following definition:

#VLAN Name—Management VLAN

#802.1Q VLAN ID—1 (if tagging is required)

All the ports are initially placed in this VLAN, and it is the only VLAN that allows you to access the management software of the EDS over the network.

Communication Between VLANs

If the devices connected to a VLAN need to communicate to devices on a different VLAN, a router or Layer 3 switching device with connections to both VLANs needs to be installed. Communication between VLANs can only take place if they are all connected to a routing or Layer 3 switching device.

VLANs: Tagged and Untagged Membership

Your EDS supports 802.1Q VLAN tagging, a system that allows traffic for multiple VLANs to be carried on a single physical (backbone, trunk) link. When setting up VLANs you need to understand when to use untagged and tagged membership of VLANs. Quite simply, if a port is on a single VLAN it can be an untagged member, but if the port needs to be a member of multiple VLANs, tagged membership must be defined.

Typically end-stations (for example, clients) will be untagged members of one VLAN, defined as “Access Port” in EDS, while inter-Switch connections will be tagged members of all VLANs, defined as “Trunk Port” in EDS.

The IEEE Std 802.1Q-1998 defines how VLANs operate within an open packet-switched network. An 802.1Q compliant packet carries additional information that allows a switch to determine which VLAN the port belongs to. If a frame is carrying the additional information, it is known as a tagged frame.

To carry multiple VLANs across a single physical (backbone, trunk) link, each packet must be

3-36

Image 52
Contents Moxa EtherDevice Switch User’s Manual EDS-508 Series Second Edition, NovemberMoxa EtherDevice Switch EDS User’s Manual Copyright NoticeTrademarks DisclaimerTable of Contents Chapter EDS Configurator GUI Introduction Moxa EtherDevice Switch Package ChecklistInside the Future of Industrial Ethernet Technology Industrial vs. CommercialFeatures Useful Utility and Remote ConfigurationAdvanced Industrial Networking Capability Designed for Industrial ApplicationsPage Getting Started Using the RS-232 Serial Console 115200, None, 8, 1, VT100 Connection CautionEDS-508 Series User’s Manual Getting Started Using the Telnet Console Key FunctionEDS-508 Series User’s Manual Getting Started Using Web Configuration For details Page Featured Functions Configuring Basic Settings Switch Name Setting Descriptions Factory DefaultSwitch Location Setting Descriptions Factory Default Switch Description Setting Descriptions Factory DefaultPassword Disable Telnet/Web ConsoleSetting Descriptions Factory Default Account NameAccessible IP Password Setting# Hosts on the specific subnet can access the NE-4000T # Any host can access the NE-4000TPort Enable/Disable PortName Port Type Port Transmission SpeedFDX Flow Control Auto IP Configuration Switch IP AddressSwitch Subnet Mask Default GatewayTime Current Time Setting Description Factory DefaultDNS IP Address Time Zone Setting Description Factory Default Current Date Setting Description Factory DefaultSystem Up Time Tftp Server IP/Name Setting Description Factory Default System File Update-By Remote TftpLog file path and name Setting Description Factory Default System File Update-By Local Import/Export Configuration File ExportConfiguration File Import Log File ExportFactory Default Using Port TrunkingConcept of Port Trunking Port Trunking Settings Configuring Port TrunkingTrunking settings Port setting information Using SnmpEnable/Disable Configuring Snmp Snmp Read/Write Settings Snmp VersionsV1, V2c Read Community V1, V2c Read/Write CommunityAdmin Auth. Type For Snmp V1, V2c, V3 and V3 only Admin Data Encryption Key For Snmp V1, V2c, V3 and V3 onlyUser Auth. Type For Snmp V1, V2c, V3 and V3 only User Data Encryption Key For Snmp V1, V2c, V3 and V3 onlyUsing Communication Redundancy Trap SettingsPrivate MIB information Concept of Turbo RingWhen the number of EDS units in the Turbo Ring is even Page Switch a Coupler Configuring Turbo Ring Concept of STP/RSTP What is STP? How STP Works STP RequirementsSTP Configuration STP ReconfigurationHow Rstp Differs from STP Port Speed Path Cost 802.1D Edition 802.1w-2001Using STP on a Network with Multiple VLANs STP ExampleConfiguring STP/RSTP Root/Not Root Protocol of RedundancyBridge priority Hello time secEnable STP per Port Configuration Limits of RSTP/STPMax. Age sec Port PriorityUsing Traffic Prioritization What is Traffic Prioritization?Concept of Traffic Prioritization How Traffic Prioritization WorksIeee 802.1p Priority Level Ieee 802.1D Traffic Type Differentiated Services DiffServ Traffic MarkingTraffic Prioritization QoS Classification Configuring Traffic PrioritizationTraffic Queues Default Port Priority Queuing MechanismInspect TOS Inspect COSCoS Mapping TOS/DiffServ MappingUsing Virtual LAN What is a VLAN?Concept of Virtual LAN Vlan Benefits of VLANsVLANs and Moxa EtherDevice Switch Management VlanCommunication Between VLANs VLANs Tagged and Untagged MembershipSample Applications of VLANs using Moxa EtherDevice Switch Device a Switch a Switch BConfiguring 802.1Q Vlan Vlan Port SettingsManagement Vlan Setting Port PvidPort Fixed Vlan List Tagged Port Forbidden Vlan ListUsing Multicast Filtering What is an IP Multicast?Concept of Multicast Filtering Vlan TableMulticast Filtering Network without multicast filteringConfiguring Multicast Filtering Multicast Filtering and Moxa EtherDevice SwitchIgmp Multicast Filtering Enabling Igmp SnoopingIgmp Snooping Settings Querier interval Igmp Snooping Enable GlobalIgmp Snooping Enable per Vlan Static Multicast Router PortUsing Rate Limiting Add Static Multicast MACIgmp Table Add New Static Multicast Address to the ListConfiguring Rate Limiting Ingress PolicyRate of Low Priority Queue Rate of Normal Priority QueueUsing Port Lock Adding a Static Unicast MAC AddressRate of Medium Priority Queue Rate of High Priority QueueUsing Auto Warning Configuring Port LockConfiguring Email Warning Add Static Unicast MAC AddressEmail Alarm Events Settings Configuring Email SettingsActivate your settings and test email if necessary Event TypesMoxaEtherDeviceSwitch0001@SwitchLocation Email SettingsPort Event Configuring Relay Warning Configuring Relay Event TypesMail Server IP/Name Email AddressRelay Alarm Events Settings Activate your settingsRelay Alarm List Using Line-Swap-Fast-RecoveryOverride relay alarm settings Configuring Line-Swap Fast Recovery Using Set Device IPEnable Line-Swap-Fast-Recovery Configuring Set Device IP Set up the connected devicesUsing Diagnosis Mirror PortDesired IP Address Output data streamMonitor by Switch Using MonitorPing Monitor by Port Using the MAC Address Table ALLUsing Event Log Page EDS Configurator GUI Starting EDS Configurator Broadcast SearchSearch by IP address Upgrade Firmware Modify IP AddressExport Configuration Import Configuration Unlock Server LockedUnlocked BlankLocked Fixed FixedUnlocked Fixed MIB Groups Page Specifications TechnologyInterface Optical FiberPower MechanicalEnvironment Regulatory ApprovalsService Information Moxa Internet Services Following services are providedMoxa Product % EDS-508 Problem Report FormSerial Number Product Return Procedure