Moxa Technologies 2140 user manual Rear Panel, COM1 & COM, General I/O terminal block

Page 13

Introduction

Rear Panel

8: COM1 & COM 2

There are 2 COM ports on VPort 2140’s rear panel.

a.COM 1 (RS-232): This RS-232 serial port can connect with an RS-232 PTZ camera. For RS-485 PTZ cameras, the administrator can use the General I/O terminal block’s COM 1 (RS-485) .

b.COM 2 (RS-232): This RS-232 serial port can connect to a modem, or you can use the included null modem cable to utilize a dial-up network when Ethernet is not available. If the Video Server is connected to the network via the Ethernet interface, you can also use this RS-232 serial port to control an RS-232 PTZ camera.

9 & 10: General I/O terminal block

VPort 2140 provides a very flexible general I/O interface that can be used with security devices, such as sensors, alarms, lighting fixtures, or door locks. Two green connectors are included in the package to connect external devices. The general I/O terminal block has 20 pins for device control. These pins can be divided into three categories based on their functions, including power source, RS-485 and digital inputs and outputs.

No.

Pin description

 

Regulation

1

Output

-

Power Output, Max. 500 mA at 12V DC

2

12 VDC

+

 

3

Relay

NC

Normal Close, Max. 1A, 24V DC or 0.5A, 125V AC

4

C

Common, Short with NC at initial state

Output 2

5

NO

Normal Open, Max. 1A, 24V DC or 0.5A, 125V AC

 

6

Relay

NC

Normal Close, Max. 1A, 24V DC or 0.5A, 125V AC

7

C

Common, Short with NC at initial state

Output 1

8

NO

Normal Open, Max. 1A, 24V DC or 0.5A, 125V AC

 

9

COM 1

+

RS-485, Data+

10

RS-485

-

RS-485, Data-

11

Input

+

External Power Input, Min. 1.5A, 12-15V AC or DC

12

12 VDC

-

 

13

Digital

+

Max. 50 mA, 12V DC

14

Input 1

-

Ground

15

Digital

+

Max. 50 mA, 12V DC

16

Input 2

-

Ground

17

Digital

+

Max. 50 mA, 12V DC

18

Input 3

-

Ground

19

Digital

+

Max. 50 mA, 12V DC

20

Input 4

-

Ground

a.Power Source: There are 2 ways to connect to the power source. One is using the power adaptor. The other is using Pin 11 and Pin 12 of the terminal block, which are for DC power input. This DC power source can be either AC or DC, and should fall in the output

VPort 2140 User’s Manual 1-7

Image 13
Contents First Edition, March VPort User’s ManualTrademarks Copyright NoticeDisclaimer Before getting started Table of Contents Chapter Advanced Applications Page Introduction Overview Product Features Package ChecklistEthernet Connection Typical ApplicationsModem Dial-up Connection Front Panel Product DescriptionsNetwork LEDs ACTIVE, LINK, and FDX Mode ConditionName Description Work Status COM1 & COM Rear PanelGeneral I/O terminal block Pin description RegulationInput 12 VDC 11 10/100 Mbps EthernetGetting Started Before Getting Started Setting up an Ethernet EnvironmentBefore Getting Started Setting up an Ethernet EnvironmentCable Connection Front PanelRear Panel Running the IP Installer ProgramUsing the IP Installer Program Powering on the VPort 2140 Video ServerAssigning an IP Address to VPort 2140 Video Server Getting Started Using DOS Commands under Windows Accessing VPort 2140 Video Server for the First TimeNull Modem Setting up a Modem EnvironmentModem Powering on VPort 2140 Video ServerInstalling a new modem Configuring a Modem Under Windows 2000 EnvironmentVPort 2140 User’s Manual Modem Mode Click on Start Control Panel Modems Setting up a new connectionVPort 2140 User’s Manual Getting Started Modem Mode Null Modem ModeMounting VPort Panel MountingAccessing VPort 2140 Video Server for the First Time Authentication Accessing VPort 2140 Video ServerOpening Your Browser Installing the Plug-in Application Functions Featured on the MainImage Mode and Text Mode Image ModeVideo Quality Selection Logo and Host NameImage Size Selection Custom Camera Commands System ConfigurationCamera View selection Relay Output ControlPage System Configuration Restore facotry default settings Reset system Using Setup Wizard System Configuration Via Web AccessSystem Using the Application WizardHost name Surveillance SystemSecurity Root passwordDate and Time Reset network at next boot Snapshot modeNetwork Add userHttp GeneralSave the modification FTPColor, Default size, and Default quality Image settingVideo Show Time stamp in image and Text on imagePreset position setting of Motorized PTZ camera Camera SettingMotion Detection Camera typeCOM 1 & COM Default Video SourceModulation RS-232 RS-485 SpeedPort Settings Interface modePurpose Application Custom commandLevel Weekly scheduleShow alert in image Event operationTrigger Condition Trigger ActionSend Snapshot by Email or FTP Sequential ModeView Snapshot SaveHomepage layout DemoLogo graph View log file Web page display modeLogo link Background graphView parameters Factory defaultVideo Server Initial Configuration file System Configuration Via FTPFrom 12 to Lime, 10-aqua, 11-fuchsia, 12-silver Or 1024 to String of max characters Or RS485 Or YES to activate external script Telnet Commands System Configuration Via TelnetSystem core debugging Monitor changed status of digital inputsReset network for new settings Skip installation at next bootRestore factory default settings Reset systemAdvanced Applications URL Commands for DI/DO & Camera’s Actions SettingVideo Embedded in Customers’ Homepage Capturing Up-to-date Still ImagesGetting snapshot via URL Getting snapshot via FTPDownload Event-triggered Snapshots File name Pre-alarm Upon alarm Post-alarmGetting triggered snapshots via URL Getting triggered snapshots via FTPCustomizing Graphics in Homepage Command Script for DI/DO & Camera’s Actions SettingObject File name Maximal size Parameter Explanations Command formatEvent OperatorPractical Examples Command line DescriptionDrive digital outputs URL Commands for DI/DO & Camera’s Actions SettingMoving motorized camera in PTZ direction Recalling camera positionRestore Factory Default Settings via URL URL Commands for System MaintenanceDownload System Log via FTP Restart System via URLUpgrading System Firmware Using Upgrade Wizard to Upgrade Firmware Easily Using FTP to Upgrade Firmware Page Troubleshooting Frequently Asked Questions Power On Self Test PostLED pattern after Post Failed function Troubleshooting Troubleshooting VPort 2140 User’s Manual URL URL Commands of Video ServerName Value Description Resource name Reference URLNetwork Configuration URL Video Configuration URL COM 1 Configuration URL Camera custom command configuration URL Custom camera configuration URL Motion detection configuration URL VPort 2140 User’s Manual A-9 Page Camera model Baud rate Data bits Stop bit Parity bit Settings of Supported PTZ CamerasPage Camera Control Cable Page Time Zone Table VPort 2140 User’s Manual Technical Specifications General I/O Service Information Following services are provided Moxa Internet ServicesMoxa Product VPort Serial Number Problem Report FormProduct Return Procedure

2140 specifications

Moxa Technologies has established a strong reputation in the realm of industrial networking and communications, and one of their standout products is the Moxa Technologies 2140. This device serves as a versatile and robust solution for various applications in industrial settings.

The Moxa 2140 is primarily recognized for its ability to seamlessly integrate serial devices into Ethernet networks. This capability is essential in modern industrial environments, where legacy equipment must often communicate with newer systems. The device functions as a serial device server, converting serial data into Ethernet packets, enabling efficient data transmission without compromising on speed or reliability.

One of the key features of the Moxa 2140 is its support for multiple serial communication protocols, including RS-232, RS-422, and RS-485. This wide compatibility ensures that users can connect a diverse range of devices, from older machinery to contemporary sensors, without needing extensive modifications. The Moxa 2140 can handle various communication speeds, allowing for flexibility in different industrial scenarios.

In addition to its protocol support, the Moxa 2140 boasts dual Ethernet ports, which facilitate network redundancy and enhanced reliability. This capability is crucial for industrial applications that demand continuous uptime, as it minimizes the risk of network failures. The device supports both static and dynamic IP address configurations, simplifying integration into existing networks.

The Moxa 2140 is equipped with advanced security features, including secure data transmission via SSH and HTTPS. This ensures that sensitive industrial data remains protected from unauthorized access, a critical consideration in today’s cybersecurity landscape. The device also includes built-in support for SNMP (Simple Network Management Protocol), enabling administrators to monitor network status and troubleshoot issues efficiently.

Another noteworthy characteristic of the Moxa 2140 is its rugged design, built to withstand harsh industrial environments. Its robust housing protects against dust, moisture, and temperature fluctuations, making it suitable for deployment in factories, outdoor settings, and other challenging conditions.

Overall, the Moxa Technologies 2140 is a powerful and flexible tool that meets the demands of modern industrial communications. Its combination of protocol support, dual Ethernet ports, security features, and durability make it a preferred choice for companies looking to enhance their communication infrastructure while ensuring versatility and reliability in their operations.