Moxa Technologies 2140 user manual Using FTP to Upgrade Firmware

Page 73

Upgrading System Firmware

Using FTP to Upgrade Firmware

Step 1: Use the FTP program and change the working directory to the local folder where FLASH.BIN resides.

Step 2: Connect to Video Server with user name as “root” and password.

Step 3: Use the PUT command to upload FLASH.BIN to Video Server. The file size is almost 1.8 MB. It will take approximately 3 seconds over a local network, 2 minutes by a null modem connection, or 6 minutes by modem, but the actual time will depend on the status of the user's network.

Step 4: After upload is complete, close the connection.

If the received FLASH.BIN is checked without error, Video Server will update the software in Flash memory and restart automatically. When Video Server starts writing firmware, both CONNECT and SERIAL LED indicators will stay on until the system restarts (this takes about 30 to 40 seconds). Users must keep the power stable during the update process. After the system restarts, Video Server may need installation depending on whether the Reset network at next boot option is enabled or not. After Video Server boots up, reload the web page in the browser.

We strongly recommend that you use the upgrade wizard to upgrade the firmware for a Microsoft Operating System, since if the power fails during the software upgrade, the program in the memory of Video Server may be destroyed permanently. If Video Server cannot restart properly, ask the dealer for technical service.

For customizing your VPort’s settings, we strongly recommend that you download config.ini via FTP before you upgrade the firmware. The risk is that once the firmware has been upgraded, the settings in config.ini might be restored to the the initial settings. For this reason, after the firmware is upgraded, you need to upload the config.ini and overwrite the one existing in your VPort. In this way, you don’t have to configure your VPort’s settings again.

VPort 2140 User’s Manual 6-3

Image 73
Contents First Edition, March VPort User’s ManualTrademarks Copyright NoticeDisclaimer Before getting started Table of Contents Chapter Advanced Applications Page Introduction Overview Product Features Package ChecklistEthernet Connection Typical ApplicationsModem Dial-up Connection Front Panel Product DescriptionsNetwork LEDs ACTIVE, LINK, and FDX Mode ConditionName Description Work Status COM1 & COM Rear PanelGeneral I/O terminal block Pin description RegulationInput 12 VDC 11 10/100 Mbps EthernetGetting Started Before Getting Started Setting up an Ethernet EnvironmentBefore Getting Started Setting up an Ethernet EnvironmentCable Connection Front PanelRear Panel Running the IP Installer ProgramUsing the IP Installer Program Powering on the VPort 2140 Video ServerAssigning an IP Address to VPort 2140 Video Server Getting Started Using DOS Commands under Windows Accessing VPort 2140 Video Server for the First TimeNull Modem Setting up a Modem EnvironmentModem Powering on VPort 2140 Video ServerInstalling a new modem Configuring a Modem Under Windows 2000 EnvironmentVPort 2140 User’s Manual Modem Mode Click on Start Control Panel Modems Setting up a new connectionVPort 2140 User’s Manual Getting Started Modem Mode Null Modem ModeMounting VPort Panel MountingAccessing VPort 2140 Video Server for the First Time Authentication Accessing VPort 2140 Video ServerOpening Your Browser Installing the Plug-in Application Functions Featured on the MainImage Mode and Text Mode Image ModeVideo Quality Selection Logo and Host NameImage Size Selection Custom Camera Commands System ConfigurationCamera View selection Relay Output ControlPage System Configuration Restore facotry default settings Reset system Using Setup Wizard System Configuration Via Web AccessSystem Using the Application WizardHost name Surveillance SystemSecurity Root passwordDate and Time Reset network at next boot Snapshot modeNetwork Add userHttp GeneralSave the modification FTPColor, Default size, and Default quality Image settingVideo Show Time stamp in image and Text on imagePreset position setting of Motorized PTZ camera Camera SettingMotion Detection Camera typeCOM 1 & COM Default Video SourceModulation RS-232 RS-485 SpeedPort Settings Interface modePurpose Application Custom commandLevel Weekly scheduleShow alert in image Event operationTrigger Condition Trigger ActionSend Snapshot by Email or FTP Sequential ModeView Snapshot SaveHomepage layout DemoLogo graph View log file Web page display modeLogo link Background graphView parameters Factory defaultVideo Server Initial Configuration file System Configuration Via FTPFrom 12 to Lime, 10-aqua, 11-fuchsia, 12-silver Or 1024 to String of max characters Or RS485 Or YES to activate external script Telnet Commands System Configuration Via TelnetSystem core debugging Monitor changed status of digital inputsReset network for new settings Skip installation at next bootRestore factory default settings Reset systemAdvanced Applications URL Commands for DI/DO & Camera’s Actions SettingVideo Embedded in Customers’ Homepage Capturing Up-to-date Still ImagesGetting snapshot via URL Getting snapshot via FTPDownload Event-triggered Snapshots File name Pre-alarm Upon alarm Post-alarmGetting triggered snapshots via URL Getting triggered snapshots via FTPCustomizing Graphics in Homepage Command Script for DI/DO & Camera’s Actions SettingObject File name Maximal size Parameter Explanations Command formatEvent OperatorPractical Examples Command line DescriptionDrive digital outputs URL Commands for DI/DO & Camera’s Actions SettingMoving motorized camera in PTZ direction Recalling camera positionRestore Factory Default Settings via URL URL Commands for System MaintenanceDownload System Log via FTP Restart System via URLUpgrading System Firmware Using Upgrade Wizard to Upgrade Firmware Easily Using FTP to Upgrade Firmware Page Troubleshooting Frequently Asked Questions Power On Self Test PostLED pattern after Post Failed function Troubleshooting Troubleshooting VPort 2140 User’s Manual URL URL Commands of Video ServerName Value Description Resource name Reference URLNetwork Configuration URL Video Configuration URL COM 1 Configuration URL Camera custom command configuration URL Custom camera configuration URL Motion detection configuration URL VPort 2140 User’s Manual A-9 Page Camera model Baud rate Data bits Stop bit Parity bit Settings of Supported PTZ CamerasPage Camera Control Cable Page Time Zone Table VPort 2140 User’s Manual Technical Specifications General I/O Service Information Following services are provided Moxa Internet ServicesMoxa Product VPort Serial Number Problem Report FormProduct Return Procedure

2140 specifications

Moxa Technologies has established a strong reputation in the realm of industrial networking and communications, and one of their standout products is the Moxa Technologies 2140. This device serves as a versatile and robust solution for various applications in industrial settings.

The Moxa 2140 is primarily recognized for its ability to seamlessly integrate serial devices into Ethernet networks. This capability is essential in modern industrial environments, where legacy equipment must often communicate with newer systems. The device functions as a serial device server, converting serial data into Ethernet packets, enabling efficient data transmission without compromising on speed or reliability.

One of the key features of the Moxa 2140 is its support for multiple serial communication protocols, including RS-232, RS-422, and RS-485. This wide compatibility ensures that users can connect a diverse range of devices, from older machinery to contemporary sensors, without needing extensive modifications. The Moxa 2140 can handle various communication speeds, allowing for flexibility in different industrial scenarios.

In addition to its protocol support, the Moxa 2140 boasts dual Ethernet ports, which facilitate network redundancy and enhanced reliability. This capability is crucial for industrial applications that demand continuous uptime, as it minimizes the risk of network failures. The device supports both static and dynamic IP address configurations, simplifying integration into existing networks.

The Moxa 2140 is equipped with advanced security features, including secure data transmission via SSH and HTTPS. This ensures that sensitive industrial data remains protected from unauthorized access, a critical consideration in today’s cybersecurity landscape. The device also includes built-in support for SNMP (Simple Network Management Protocol), enabling administrators to monitor network status and troubleshoot issues efficiently.

Another noteworthy characteristic of the Moxa 2140 is its rugged design, built to withstand harsh industrial environments. Its robust housing protects against dust, moisture, and temperature fluctuations, making it suitable for deployment in factories, outdoor settings, and other challenging conditions.

Overall, the Moxa Technologies 2140 is a powerful and flexible tool that meets the demands of modern industrial communications. Its combination of protocol support, dual Ethernet ports, security features, and durability make it a preferred choice for companies looking to enhance their communication infrastructure while ensuring versatility and reliability in their operations.