Moxa Technologies 2140 user manual General, Http

Page 41

System Configuration

will automatically operate normally after being restarted after a power loss.

2. Use this IP whenever system boots = Reset network at next boot

In this case, the installation process must be performed again when system reboots. This is the default setting.

You can ignore this option if you are using the Modem Dial-up connection.

General

Administrators may need to modify the network settings to connect to an existing network, since the subnet mask in some broadband service may differ from the default value of 255.255.255.0, and service providers may assign more specific network settings. Administrators should change the configuration to the settings given by the service provider. The configuration may include IP address, Subnet mask, Default router, Primary DNS server, and Secondary DNS server.

After changing network settings, make sure to uncheck the “Reset network at next boot option” to avoid the installation starting up again the next time the system restarts. Otherwise, existing network settings will be erased at the next start.

In addition, administrators can limit the bandwidth used by a VPort 2140 Video Server according to priority and importance of location. Limiting bandwidth is useful for balancing network utilization when multiple VPorts are installed on the same network. This method is more effective than just changing image quality, and is able to achieve better performance with adequate image size and quality.

HTTP

For security or network integration, administrators can hide the server from the general HTTP port by changing the default HTTP port of 80 to a different port number. Administrators should have enough network knowledge to change the default port.

SMTP

VPort 2140 Video Server not only plays the role of server, but also actively connects to outside servers to send alarm messages or snapshots. If the administrator has set up some applications in either event mode or sequential mode, the VPort will send out snapshots once these conditions occur.

1.To activate the e-mail function, enter correct settings for SMTP (mail) server’s domain name/IP address and Recipient email address.

2.Secondary SMTP (mail) server’s domain name/IP address and Secondary email address are provided for a backup connection when the primary SMTP server fails.

3.Return email address is the address the email is returned to when the SMTP server rejects email due to failure. Some ISPs may reject the email if the address is invalid.

If the settings are correct when the VPort starts up, it will send out a system log via e-mail instead of uploading the log via FTP. Note that if the Return email address is not set, the e-mail system will not work properly.

VPort 2140 User’s Manual 4-7

Image 41
Contents First Edition, March VPort User’s ManualDisclaimer Copyright NoticeTrademarks Before getting started Table of Contents Chapter Advanced Applications Page Introduction Overview Product Features Package ChecklistModem Dial-up Connection Typical ApplicationsEthernet Connection Front Panel Product DescriptionsName Description Work Status Mode ConditionNetwork LEDs ACTIVE, LINK, and FDX COM1 & COM Rear PanelGeneral I/O terminal block Pin description RegulationInput 12 VDC 11 10/100 Mbps EthernetGetting Started Before Getting Started Setting up an Ethernet EnvironmentBefore Getting Started Setting up an Ethernet EnvironmentCable Connection Front PanelRear Panel Running the IP Installer ProgramAssigning an IP Address to VPort 2140 Video Server Powering on the VPort 2140 Video ServerUsing the IP Installer Program Getting Started Using DOS Commands under Windows Accessing VPort 2140 Video Server for the First TimeNull Modem Setting up a Modem EnvironmentModem Powering on VPort 2140 Video ServerInstalling a new modem Configuring a Modem Under Windows 2000 EnvironmentVPort 2140 User’s Manual Modem Mode Click on Start Control Panel Modems Setting up a new connectionVPort 2140 User’s Manual Getting Started Modem Mode Null Modem ModeMounting VPort Panel MountingAccessing VPort 2140 Video Server for the First Time Opening Your Browser Accessing VPort 2140 Video ServerAuthentication Installing the Plug-in Application Functions Featured on the MainImage Mode and Text Mode Image ModeImage Size Selection Logo and Host NameVideo Quality Selection Custom Camera Commands System ConfigurationCamera View selection Relay Output ControlPage System Configuration Restore facotry default settings Reset system Using Setup Wizard System Configuration Via Web AccessSystem Using the Application WizardHost name Surveillance SystemDate and Time Root passwordSecurity Reset network at next boot Snapshot modeNetwork Add userHttp GeneralSave the modification FTPColor, Default size, and Default quality Image settingVideo Show Time stamp in image and Text on imagePreset position setting of Motorized PTZ camera Camera SettingMotion Detection Camera typeCOM 1 & COM Default Video SourceModulation RS-232 RS-485 SpeedPurpose Interface modePort Settings Application Custom commandLevel Weekly scheduleShow alert in image Event operationTrigger Condition Trigger ActionSend Snapshot by Email or FTP Sequential ModeView Snapshot SaveLogo graph DemoHomepage layout View log file Web page display modeLogo link Background graphView parameters Factory defaultVideo Server Initial Configuration file System Configuration Via FTPFrom 12 to Lime, 10-aqua, 11-fuchsia, 12-silver Or 1024 to String of max characters Or RS485 Or YES to activate external script Telnet Commands System Configuration Via TelnetSystem core debugging Monitor changed status of digital inputsReset network for new settings Skip installation at next bootRestore factory default settings Reset systemAdvanced Applications URL Commands for DI/DO & Camera’s Actions SettingVideo Embedded in Customers’ Homepage Capturing Up-to-date Still ImagesGetting snapshot via URL Getting snapshot via FTPDownload Event-triggered Snapshots File name Pre-alarm Upon alarm Post-alarmGetting triggered snapshots via URL Getting triggered snapshots via FTPObject File name Maximal size Command Script for DI/DO & Camera’s Actions SettingCustomizing Graphics in Homepage Parameter Explanations Command formatEvent OperatorPractical Examples Command line DescriptionDrive digital outputs URL Commands for DI/DO & Camera’s Actions SettingMoving motorized camera in PTZ direction Recalling camera positionRestore Factory Default Settings via URL URL Commands for System MaintenanceDownload System Log via FTP Restart System via URLUpgrading System Firmware Using Upgrade Wizard to Upgrade Firmware Easily Using FTP to Upgrade Firmware Page Troubleshooting LED pattern after Post Failed function Troubleshooting Power On Self Test PostFrequently Asked Questions Troubleshooting VPort 2140 User’s Manual URL URL Commands of Video ServerName Value Description Resource name Reference URLNetwork Configuration URL Video Configuration URL COM 1 Configuration URL Camera custom command configuration URL Custom camera configuration URL Motion detection configuration URL VPort 2140 User’s Manual A-9 Page Camera model Baud rate Data bits Stop bit Parity bit Settings of Supported PTZ CamerasPage Camera Control Cable Page Time Zone Table VPort 2140 User’s Manual Technical Specifications General I/O Service Information Following services are provided Moxa Internet ServicesMoxa Product VPort Serial Number Problem Report FormProduct Return Procedure

2140 specifications

Moxa Technologies has established a strong reputation in the realm of industrial networking and communications, and one of their standout products is the Moxa Technologies 2140. This device serves as a versatile and robust solution for various applications in industrial settings.

The Moxa 2140 is primarily recognized for its ability to seamlessly integrate serial devices into Ethernet networks. This capability is essential in modern industrial environments, where legacy equipment must often communicate with newer systems. The device functions as a serial device server, converting serial data into Ethernet packets, enabling efficient data transmission without compromising on speed or reliability.

One of the key features of the Moxa 2140 is its support for multiple serial communication protocols, including RS-232, RS-422, and RS-485. This wide compatibility ensures that users can connect a diverse range of devices, from older machinery to contemporary sensors, without needing extensive modifications. The Moxa 2140 can handle various communication speeds, allowing for flexibility in different industrial scenarios.

In addition to its protocol support, the Moxa 2140 boasts dual Ethernet ports, which facilitate network redundancy and enhanced reliability. This capability is crucial for industrial applications that demand continuous uptime, as it minimizes the risk of network failures. The device supports both static and dynamic IP address configurations, simplifying integration into existing networks.

The Moxa 2140 is equipped with advanced security features, including secure data transmission via SSH and HTTPS. This ensures that sensitive industrial data remains protected from unauthorized access, a critical consideration in today’s cybersecurity landscape. The device also includes built-in support for SNMP (Simple Network Management Protocol), enabling administrators to monitor network status and troubleshoot issues efficiently.

Another noteworthy characteristic of the Moxa 2140 is its rugged design, built to withstand harsh industrial environments. Its robust housing protects against dust, moisture, and temperature fluctuations, making it suitable for deployment in factories, outdoor settings, and other challenging conditions.

Overall, the Moxa Technologies 2140 is a powerful and flexible tool that meets the demands of modern industrial communications. Its combination of protocol support, dual Ethernet ports, security features, and durability make it a preferred choice for companies looking to enhance their communication infrastructure while ensuring versatility and reliability in their operations.