Moxa Technologies C218 user manual Connection Option Opt8x and Cable Wiring, DTE Device

Page 73

Connection Option (Opt8x) and Cable Wiring

Type 1: To connect Intellio C218Turbo/PCI to a DTE device.

Opt8A/S

Straight-through Cable

PC COM2 port, Serial Printer,

Terminal, or any DTE Device

Opt8A/S

DB25 Female

RxD

2

 

2

 

TxD

3

 

3

 

CTS

4

 

4

 

RTS

5

 

5

 

DTR

6

 

6

DSR

20

20

GND

7

7

DCD

8

 

8

Null Modem Cable Opt8B/C

DTE Device

DB25 Male

TxD

RxD

RTS

CTS

DSR

DTR

GND

DCD

PC COM2 port, Serial Printer, Terminal, or any DTE Device

Opt8B/C

 

 

 

DTE Device

DB25 Male

 

 

 

DB25 Male

TxD

2

2

TxD

RxD

3

3

RxD

RTS

4

4

RTS

CTS

5

5

CTS

DSR

6

6

DSR

DTR

20

20

DTR

GND

7

 

7

GND

DCD

8

 

8

DCD

Intellio C218Turbo /PCI User's Manual 5-3

Image 73
Contents March 3rd Edition Intellio C218Turbo/PCI User’s ManualTrademarks Copyright NoticeDisclaimer Moxa Internet Services About This Manual Table of Contents Technical Reference TroubleshootingPCI Solution Intellio The Intelligent Multiport Serial I/O SolutionsOverview Low Host Processor OverheadAsic Design, Compact Size Powerful Serial Comm Developing ToolsSurge/Isolation Protection Major Operating System SupportCheck List FeaturesIntroduction Opt8C/Opt8D Opt8A/Opt8B/Opt8SOpt8F/Opt8Z Opt8JInstallation Guide Page Installing the Intellio C218Turbo/PCI Control Board Hardware InstallationInstalling Connection Option Opt8x Opt8J/Opt8F/Opt8Z Operating Opt8J RS-485 Mode Hardware Installation RS-422 ModePage Windows NT Software InstallationInstalling Driver Software Installation Page Uart Fifo Page Configuring Board and Port Page Updating Driver Adding/Removing BoardRemoving Driver Windows 95/98Installing Driver Yes Windows Software Installation First Time Driver Installation StagePage Click Next Port Configuration Stage Without restarting the Windows 98 system Software Installation Board and Port Ready StagePage Configuring Board and Port Page Software Installation Uart Fifo Updating driver Unix For SCO Unix or SCO OpenServer or Xenix Driver will start successfully later Moxa TTY Device Naming Convention Basic Configuration Administration Utility mxadmNon-Modem and Modem Baud Rate On Board Line Discipline Advanced ConfigurationBaud Rate Mapping Feature RTS/CTS Hardware Flow Control ResponseBoard Reset Software Installation Performance TuningDriver Removal Checking Board Initialization Status Setting Moxa Ports to TerminalPage Windows NT and Windows 95/98 InstallationUtilities PComm Programming LibrarySerial Programming Tools Diagnostic for Moxa boards only Monitor for Moxa boards under Windows NT Only Serial Programming Tools Terminal Emulator Programming the Moxa Ports Extended Unix Ioctl CommandsMobufed Mtcrts Mlowater Mstatus Mhwflow Port Monitoring Serial Programming Tools Terminal Emulator Page RS-485 Programming for Opt8J Solution Solution RS-232 Cable Wiring for Opt8A/B/C/D/S Connection Option Opt8x and Cable WiringOpt8A/S DCE, DB25 Female DTE Device Connection Option Opt8x and Cable WiringOpt8D DTE Device Opt8B/C Opt8A/S DTE Device GND RTS CTS DTR DSR DCD RS-422 Cable Wiring for Opt8J/F/Z Followings are operation modes for RS-422 RS-485 Pinouts for Opt8J RS-485 Cable Wiring for Opt8JRS-422/485 Impedance Matching Page General Troubleshooting TroubleshootingSoftware Causes and Solutions Windows NT system panic blue screen Moxa port responds too slowly or abnormal key operation Newly rebuilt kernel could not boot Page Appendix SpecificationsUnix SVR4.2 Xenix Dual-Ported RAMUart 16C550C DB62 Connector PinoutsIntellio C218Turbo/PCI Problem Report FormReturn Procedure