Lucent Technologies Release 6 Connect Adjunct Power, B2 Adapter Connecting to a Modular Plug

Models: Release 6

1 453
Download 453 pages 12.94 Kb
Page 155
Image 155

DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

5 Install and Wire Telephones and Other Equipment

 

 

Page 5-4

 

 

Connect Adjunct Power

The attendant console requires -48 VDC adjunct power from pins 7 and 8 of the information outlet. Only 3 consoles can be powered by the cabinet from the AUX connector. Power the primary console from the cabinet so it has the same power failure backup as the system.

1.For terminals needing adjunct power, wire -48 VDC and ground to appropriate pins on the terminal. See Figure 5-3. Use the 400B2 adapter when connecting local -48 VDC power to a modular plug.

 

 

 

r749428 KLC 060396

Figure Notes

 

 

1.

Flush-Mounted Information Outlet

4.

400B2 Adapter

2.

Surface-Mounted Information Outlet

5.

To Telephone

3.

To Individual Power Unit

6.

Destination Service Access Point

 

 

 

(DSAP) Power Cord

Figure 5-3. 400B2 Adapter Connecting to a Modular Plug

! CAUTION:

Do not use the 329A power unit for the attendant console. Use an 1151A, 1151A2, 1145A, or MSP-1 power unit.

Adjunct power can be provided from the equipment room or equipment closet

with an 1145B power unit. See ‘1145BPower Supply’’ on page 5-45.

Adjunct power can also be provided locally at the telephone or console with a

1151A or 1151A2 power unit. See ‘1151APower Supply’’ on page 5-54.