DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Add PRI Over PACCON to R6si | Page |
Since the packet bus is required with PRI Over PACCON, the TN778 Packet Control circuit pack should be added first. If the system is not equipped with a packet bus see ‘Add‘ Packet Bus to R6si’’ on page
If EPNs reside in the system, replace every TN776 EI circuit pack with a TN570 EI to provide
2.Remove an existing TN756 Tone Detector/Generator circuit pack and install the TN768, TN780, or TN419B
3.Determine port assignment of port circuit packs to be added.
4.Install the TN464 circuit pack in assigned carrier slot (as required). For example:
Port Number | 3 | B | 02 | 01 |
|
|
|
|
|
| Cabinet | Carrier | Slot | Circuit |
| (Port Network) |
|
|
|
|
|
|
|
|
5.Install the TN748B (or the
Install Cables
1. Install cables from the cabinet to the MDF as required.
Power Up System
1.At each EPN, set the main circuit breaker to ON.
2.At the PPN, set the main circuit breaker to ON.
3.The system performs a level 4 reboot, loading the system translations from the translation card or tape. Rebooting takes several minutes.
4.After the system reboot is finished and all trouble is cleared, verify the EMERGENCY TRANSFER CONTROL switch is set to AUTO. This restores the system to the normal mode.