DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
1Install and Connect Cabinets
Install System Cabinets | Page |
■Model 15A Announcement System — See Table
Table 1-1. Model 15A Announcement Equipment
| PEC Code | Description |
|
|
|
|
|
| PEC 63240 | 1 chassis and 1 BLD1 circuit pack |
|
|
|
|
|
| PEC 63241 | 1 BLD1 circuit pack |
|
|
|
|
|
| PEC 63242 | 1 chassis and 1 BLD2 circuit pack |
|
|
|
|
|
| PEC 63243 | 1 BLD2 circuit pack |
|
|
|
|
|
| PEC 63246 | 1 remote record module |
|
|
|
|
|
|
|
|
|
The BLD1 circuit pack provides 8 channels with up to 20 seconds of recording time on each channel. The BLD2 circuit pack provides 8 channels with up to 40 seconds of recording time on each channel. Each chassis can be populated with any combination of 2 BLD circuit packs.
The Model 15A Announcement System is FCC registered and does not require a voice coupler.
2.If earthquake protection is required, skip to ‘Earthquake‘ Protection Installation’’ on page
Install and Position Stratum 3 Clock Cabinet
Check the location of the AC power receptacle. The receptacle must be on a separately fused circuit that is not controlled by a wall switch. It must be located within 10 feet (3 m) of the cabinet and should be located outside the MDF area.
1.Position the clock cabinet in the designated location.
2.If earthquake protection is required, skip to ‘Earthquake‘ Protection Installation’’ on page
3.If earthquake protection is not required, level the cabinets and adjust and lock the cabinet stabilizing bolts to keep the cabinet from moving.