DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

1Install and Connect Cabinets

Install System Cabinets

Page 1-5

Model 15A Announcement System See Table 1-1 for PEC codes.

Table 1-1. Model 15A Announcement Equipment

 

PEC Code

Description

 

 

 

 

 

 

PEC 63240

1 chassis and 1 BLD1 circuit pack

 

 

 

 

 

 

PEC 63241

1 BLD1 circuit pack

 

 

 

 

 

 

PEC 63242

1 chassis and 1 BLD2 circuit pack

 

 

 

 

 

 

PEC 63243

1 BLD2 circuit pack

 

 

 

 

 

 

PEC 63246

1 remote record module

 

 

 

 

 

 

 

 

 

The BLD1 circuit pack provides 8 channels with up to 20 seconds of recording time on each channel. The BLD2 circuit pack provides 8 channels with up to 40 seconds of recording time on each channel. Each chassis can be populated with any combination of 2 BLD circuit packs.

The Model 15A Announcement System is FCC registered and does not require a voice coupler.

2.If earthquake protection is required, skip to ‘EarthquakeProtection Installation’’ on page 1-34.

Install and Position Stratum 3 Clock Cabinet

Check the location of the AC power receptacle. The receptacle must be on a separately fused circuit that is not controlled by a wall switch. It must be located within 10 feet (3 m) of the cabinet and should be located outside the MDF area.

1.Position the clock cabinet in the designated location.

2.If earthquake protection is required, skip to ‘EarthquakeProtection Installation’’ on page 1-34.

3.If earthquake protection is not required, level the cabinets and adjust and lock the cabinet stabilizing bolts to keep the cabinet from moving.