DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112 Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-112Add ISDN — PRI
5
Enter Added Translations
1. Administer the forms listed under “I nteg rated Services Digital Network —
Primary Rate Interface” in
DEFINITY Enterprise Communic ations Server Release 6 Administration and Feature Description
.
Resolve Alarms
1. Examine the alar m log. Resolve any alarms that may ex ist using
DEFINITY Enterprise Communications Server Release 6 Maintenance R6vs/si
.
Contact INADS to Enable Customer Options and
Verify Alarm Origination
Be sure the system is part of the existing INADS database by calling the INADS
Database Administrator at the Technical Service Center (TSC). Verify that INADS
can dial into the system and that the system can dial out to INADS.
As part of the system registration process, the INADS Database Administrator
enables Alarm Orig ination and enables c ustomer options.
!CAUTION:
If you do not enable Alarm Orig ination when the customer has purc hased a services contract, the system cannot rep or t any alarm to the TSC
automatically, causing the TSC to be unable to fulfill the services contrac t.
Save Translations
1. If the system is high or c ritical reliability, enter status system 1 and press
Enter to verify that the system is in the “ active/standby” mode.
2. Enter save translation and press Ente r. This instructs the system to take all
translation information in memory and write it to the translation memory
card or the tap e.
3. If the system cont ains a TN750 Announce ment circuit pac k, enter list
configuration software-version and press En ter. If Page 2 of this form
shows that recorded announc ements were saved, these announcements
can be restored u sing restore announcements and press Enter.
4. Up date bac kup tape, if nec essary.