DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Page |
Basic Multipoint Installation Distances
Figure 5-28 provides cabling information for fan-out of ISDN-BRI multi-point installations. The terminating resistor is generally located in the satellite closet. All distances assume 24 AWG (#5) (0.26 mm2) D-Inside Wire (DIW).
9
4
6
7
11
10
1
2
11
3
5
8
inst_dis CJL 030796
Figure Notes
1.
2.Terminating Resistor
3.Satellite Closet
4.Maximum Distance from
5.Maximum Distance From Satellite Closet to Work Location (250 Feet) (76 m)
6.System Cabinet
7.Terminating Endpoint 1
8.Terminating Endpoint 2
9.Work Location
10.Maximum Distance from Information Outlet to Terminating Endpoint (33 Feet) (10 m)
11.Information Outlet (Bridged Tap)