DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Multi-point Adapters

Page 5-63

Basic Multipoint Installation Distances

Figure 5-28 provides cabling information for fan-out of ISDN-BRI multi-point installations. The terminating resistor is generally located in the satellite closet. All distances assume 24 AWG (#5) (0.26 mm2) D-Inside Wire (DIW).

9

4

6

7

11

10

1

2

11

3 5

8

inst_dis CJL 030796

Figure Notes

1.S-Interface Source (TN556)

2.Terminating Resistor

3.Satellite Closet

4.Maximum Distance from S-Interface Source to Work Location (1600 Feet) (488 m)

5.Maximum Distance From Satellite Closet to Work Location (250 Feet) (76 m)

6.System Cabinet

7.Terminating Endpoint 1

8.Terminating Endpoint 2

9.Work Location

10.Maximum Distance from Information Outlet to Terminating Endpoint (33 Feet) (10 m)

11.Information Outlet (Bridged Tap)

Figure 5-28. Basic Multi-point with 1 Work Location