DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
A Connecting Fiber Optic Cables |
|
Optical | Page |
|
|
Single-Mode Fiber Link (with Attenuators)
Figure Notes |
|
| |
1. | 300A Lightwave Transceiver | 5. | TX Connector |
2. | 6. | RX Connector | |
3. | 7. | Lightguide Interconnect Unit | |
4. | Fiber Plant | 8. | Fiber Optic Cable |
Figure A-2. Typical Single-Mode Connection with Attenuator
1.Connect a
2.Connect the patchcord to the required attenuator. The attenuator must be installed in series with the strand of fiber connecting to the TX connector.
3.Repeat for the TX connector at the opposite end of the fiber link (remote EPN). A different value attenuator may be required, depending on the amount of fiber loss back to the local system.
![]()
NOTE:
If the fiber link is duplicated, route the fiber via a separate geographical path, if possible. This way, if the standard fiber link is damaged, the duplicated fiber remains in service.