DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
6Test Telephones and Other Equipment
Test | Page |
Test Music-on-Hold
Verify music is provided to a held party during any hold interval.
Test Emergency Transfer
Put system in emergency transfer mode and make call using emergency transfer telephone. There may be up to 4 Emergency Transfer switches depending on the system configuration. The switch is located on the Processor circuit pack(s) in the Processor Port Network (PPN) Control Carrier.
Test Remote Access Interface
Test the communication link between the system and the remote interface (formerly INADS) and verify the alarm notification process. Make a remote test from the remote interface to the DEFINITY System and a local test from the DEFINITY System to the remote interface.
In some countries, this remote access interface is not allowed. Contact your
Lucent Technologies representative.
Remote Test
1.Call outside personnel who will be accessing the system remotely to perform administration, maintenance, and testing.
2.Ask remote personnel to call system and login and display System Parameters Maintenance screen. The login must be successful.
![]()
NOTE:
Product Identification on the System Parameters screen must match the Product Identification administered by the local technician.
3.Have the remote personnel enter the test
4.Have the remote personnel check the appropriate trouble ticket. The trouble ticket should show “INADS,n,MINOR” in the description field to indicate a minor
5.Have the remote personnel make second call and login to the system and check the error log to verify no problems. See DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r, for error log and error code information.
6.Have the remote access personnel terminate logoff and disconnect.