DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
BRI Terminating Resistor | Page |
Closet Mounted (110RA1-12)
The
Figure 5-24 shows the wiring of the 110RA1-12. Three rows of 110D-4 connector blocks are mounted on a printed wire board along with circuit resistors and capacitors. The bottom row is designated as the input row and the top and middle rows are designated as the output rows. The circuit assembly is mounted on a standard 110A-100 pair mounting base. The 110RA1-12 is shipped with preprinted designation strips to simplify circuit identification and installation.
|
| 1 |
|
|
|
| 2 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 2 | 3 | 4 |
|
|
| 45 46 47 48 | |||||||||
3 |
|
|
|
|
|
|
|
|
|
|
|
|
| 6 | ||
|
|
|
|
|
|
|
|
|
| |||||||
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
5 |
|
|
|
|
|
|
|
|
| 7 |
|
|
|
|
|
8
Figure Notes
1.Circuit 1
2.Circuit 12
3.Output Row “A”
4.Output Row “B”
5.Input Row “C”
6.Only First Circuit Shown to All 12 Circuits (2APR) Per Block
7.
8.Printed Circuit Board Mounted on Standard 110A or 100APR Block