DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Add PRI Over PACCON to R6si

Page 5-125

Service Interruption

1.Since the addition of PRI Over PACCON requires a service interruption, notify the customer in advance as to when the addition will take place.

Disable Alarm Origination

1.Enter change system-parameters maintenance and press Enter.

2.Set the Alarm Origination Activated field to n.

! CAUTION:

If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets.

3.For some releases of software, disable Cleared Alarm Notification and Restart Notification before submitting the form.

Save Translations

1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.

2.Enter save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.

3.If the system contains a TN750 Announcement circuit pack, enter display announcements and press Enter.

If administered recorded announcements are listed, enter list configuration software-versionpress Enter. To save the announcements, enter save announcements and press Enter.

Power Down System

If the packet bus is being added:

1.At the PPN, set the main circuit breaker to OFF.

2.At each EPN, set the main circuit breaker to OFF.

Add Circuit Packs

1.To control every ISDN-PRI link in the system, a TN778 Packet Control circuit pack and TN464 ISDN-PRI circuit packs are required.