DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

3Install Management Terminal and Activate System

Administer Fiber Links (Release 6r Only)

Page 3-27

6.The Fiber Link Administration form appears. On Page 1, enter the Board Location: for ENDPOINT-1 and ENDPOINT-2. This is the cabinet, carrier, and slot that identifies the physical location of an SNI or EI circuit pack that is the first endpoint of the fiber link. Repeat for the remaining endpoints.

7.The Board Type field is display only and shows the type of circuit pack in Endpoint-1.

8.In the DS1CONV Board Location: field, enter the cabinet, carrier, and slot that identifies the physical location of DS1 Converter circuit pack in the first endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with Endpoint-2’s duplicate make up the duplicate fiber link called the B-PNC link.

9.The DS1CONV Board Type: field is display only and shows the type of DS1 Converter circuit pack in Endpoint-1. The circuit pack type in Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must be the same.

10.In the Is one endpoint remoted via a DS1 Converter Complex? field, enter y to specify that a DS1 Converter complex is used to remote 1 endpoint. If a y is entered, administer the A-PNC DS1 Converter Board Location on Page 1. The A-PNC DS1 Converter Board Type displays. Administer the A-PNC DS1 Converter (DS1CONV) Attributes on Page 2 of this form.

11.On Page 2 of the form, enter the DS1 Converter Facilities information. In the Facility Installed? field, enter y for all installed facilities (A, B, C, and D).

12.In the Bit Rate: field, enter 1.544 for T1 operation or 2.048 for E1 operation.

NOTE:

One bit rate applies for all facilities within the same DS1 Converter complex. The Bit Rate: field displays only under Facility A.

13.Enter the idle code in the Idle Code MSB (1) . . . . LSB (8): field. The default value is 11101000. It is recommended that the default value be used unless it becomes absolutely necessary to change it. The “MSB” means Most Significant Bit, the “LSB” means Least Significant Bit.

14.In the Line Coding: field, enter the line coding information. This information should match the line coding of the facility. For T1, example line coding is b8zs. For E1, example line coding is hdb3. Scroll to Page 3 and modify the fields as needed for the B-PNC.

NOTE:

If this data is not correct, wideband errors (such as multimedia call handling) may occur.

15.For T1 sites, refer to ‘T1Installations Only’’. For E1 sites, refer to ‘‘E1 Installations Only’.

Page 130
Image 130
Lucent Technologies Release 6 manual Issue