DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
3Install Management Terminal and Activate System
Administer Fiber Links (Release 6r Only) | Page |
6.The Fiber Link Administration form appears. On Page 1, enter the Board Location: for
7.The Board Type field is display only and shows the type of circuit pack in
8.In the DS1CONV Board Location: field, enter the cabinet, carrier, and slot that identifies the physical location of DS1 Converter circuit pack in the first endpoint of the duplicate fiber link.
9.The DS1CONV Board Type: field is display only and shows the type of DS1 Converter circuit pack in
10.In the Is one endpoint remoted via a DS1 Converter Complex? field, enter y to specify that a DS1 Converter complex is used to remote 1 endpoint. If a y is entered, administer the
11.On Page 2 of the form, enter the DS1 Converter Facilities information. In the Facility Installed? field, enter y for all installed facilities (A, B, C, and D).
12.In the Bit Rate: field, enter 1.544 for T1 operation or 2.048 for E1 operation.
![]()
NOTE:
One bit rate applies for all facilities within the same DS1 Converter complex. The Bit Rate: field displays only under Facility A.
13.Enter the idle code in the Idle Code MSB (1) . . . . LSB (8): field. The default value is 11101000. It is recommended that the default value be used unless it becomes absolutely necessary to change it. The “MSB” means Most Significant Bit, the “LSB” means Least Significant Bit.
14.In the Line Coding: field, enter the line coding information. This information should match the line coding of the facility. For T1, example line coding is b8zs. For E1, example line coding is hdb3. Scroll to Page 3 and modify the fields as needed for the
![]()
NOTE:
If this data is not correct, wideband errors (such as multimedia call handling) may occur.
15.For T1 sites, refer to ‘T1‘ Installations Only’’. For E1 sites, refer to ‘‘E1 Installations Only’’.