DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Add CO, FX, WATS, and PCOL

Page 5-85

Add CO, FX, WATS, and PCOL

Requirements

Each Central Office (CO), Foreign Exchange (FX), Wide Area Telecommunications Service (WATS), or Personal Central Office Line (PCOL) trunk is connected to 1 port of either an 8-port TN747 or to 1 of an assortment of non-United States CO Trunk circuit packs.

Installation

1.Determine the port assignment of the trunk from Trunk Group form. For example:

Port Number

3

A

07

01

 

Cabinet

Carrier

Slot

Circuit

 

(Port Network)

 

 

 

2.See ‘Off-Premises Station Wiring’’ on page 5-30 and install a TN747 or a non-United States CO trunk circuit pack in the assigned carrier slot (if an additional circuit pack is required).

3.Administer the forms listed under CO, FX, WATS, or PCOL Trunk Group in DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.

Page 236
Image 236
Lucent Technologies Release 6 manual Add CO, FX, WATS, and Pcol, Requirements, Installation