5Install and Wire Telephones and Other Equipment

Add CallVisor ASAI

Page 5-120

Save Translations

1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.

2.Enter save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.

3.If the system contains a TN750 Announcement circuit pack, enter list configuration software-versionand press Enter. If Page 2 of this form shows that recorded announcements were saved, restore these announcements using restore announcements and press Enter.

4.Update backup tape, if required.

Page 271
Image 271
Lucent Technologies Release 6 manual Save Translations