5Install and Wire Telephones and Other Equipment
Adjunct Power Connections | Page |
Adjunct Power Connections
Figure 5-9 shows 3 typical connection locations for adjunct power. Adjunct power for station equipment may be supplied from the equipment room, satellite location, or the work location.
4
|
|
| adjunct_1 PDH 062696 |
Figure Notes |
|
| |
1. | Typical Display Telephone | 9. | 100P6A Patch Cord or Jumpers |
2. | Adjunct Power Supply (Such as 1151A or | 10. | System Side of MDF |
| 1151A2) | 11. | |
|
| ||
3. | 400B2 Adapter |
| Analog Line Circuit Pack |
4. | Information Outlet | 12. | Equipment Room |
5. | 13. | Satellite Location | |
6. | Satellite Site or Adapter Location | 14. | Work Location |
7. | 15. | Power From Bulk Power Source (Such | |
8. | Station Side of Main Distribution Frame |
| as 1145B) |
|
| ||
Figure 5-9. Example Adjunct Power Connections
For Figure
a.If 25 telephones connect to the system and all 25 telephones need adjunct power, install the adjunct power supply in the equipment room.
b. If only 10 of the telephones need adjunct power, install the adjunct power supply at the satellite location.
c. If only 1 telephone needs adjunct power, install the adjunct power supply at the work location.