DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Adjunct Power Connections

Page 5-14

Adjunct Power Connections

Figure 5-9 shows 3 typical connection locations for adjunct power. Adjunct power for station equipment may be supplied from the equipment room, satellite location, or the work location.

4

 

 

 

adjunct_1 PDH 062696

Figure Notes

 

 

1.

Typical Display Telephone

9.

100P6A Patch Cord or Jumpers

2.

Adjunct Power Supply (Such as 1151A or

10.

System Side of MDF

 

1151A2)

11.

25-Pair Cable to System Cabinet

 

 

3.

400B2 Adapter

 

Analog Line Circuit Pack

4.

Information Outlet

12.

Equipment Room

5.

4-Pair D-Inside Wire (DIW) Cable

13.

Satellite Location

6.

Satellite Site or Adapter Location

14.

Work Location

7.

25-Pair D-Inside Wire (DIW) Cable

15.

Power From Bulk Power Source (Such

8.

Station Side of Main Distribution Frame

 

as 1145B)

 

 

Figure 5-9. Example Adjunct Power Connections

For Figure 5-9, the following example is used:

a.If 25 telephones connect to the system and all 25 telephones need adjunct power, install the adjunct power supply in the equipment room.

b. If only 10 of the telephones need adjunct power, install the adjunct power supply at the satellite location.

c. If only 1 telephone needs adjunct power, install the adjunct power supply at the work location.