DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Page |
Off-Premises Station Wiring
The cabling outside the building for
!
CAUTION:
Only an
a
1.Connect an A25D cable between the RJ21X network interface and a
sneak fuse panel. See ‘Install‘ Sneak Fuse Panels’’ in Chapter 2, ‘Install‘ Telecommunications Cabling’’.
2.At the MDF, connect jumper wires between 1 row/connecting block in the green field and up to 3 rows/connecting blocks in the purple field to concentrate the analog line pairs.
3.Connect an A25D cable between the sneak fuse panel and the
4.Install a green label on the
5.Administer per DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.